My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1520 W MARINE VIEW DR 2018-01-01 MF Import
>
Address Records
>
W MARINE VIEW DR
>
1520
>
1520 W MARINE VIEW DR 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/25/2019 9:32:46 AM
Creation date
2/27/2017 6:23:25 AM
Metadata
Fields
Template:
Address Document
Street Name
W MARINE VIEW DR
Street Number
1520
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
295
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
16." <br />( 17." <br />I ; <br />� � . <br />IB.� <br />19' <br />�.' <br />' 21.' <br />7t.' <br />23.' <br />24.' <br />�. � . <br />26.' <br />27. <br />R <br />Ederior (court) walls within .................... feet of <br />lines should bc cf ...:........... •hour construction. <br />Sedion ................ .. 03 (a). <br />Dpeninss in eaterior (court) walls within ............ <br />feet oi property lines should be protected with <br />three•fourths•haur tire assemblies. Section . <br />.................... 03 (b). <br />Usable space under the first 11oor except in <br />Group I(J), Occupancies should be enclosed <br />as required in Section 1703. <br />Fire�resistive construction for structural frame <br />elements in the exterior walls should complY <br />with Footnote No. 1 ot Table No. 17•A and <br />Sect(on ......................... See Sectfon 1702 tor <br />clarititation. � <br />Building paper should be applied to exterior <br />walls es specified in Section 1707 (a). <br />� <br />Enc!osurcs for floor openings should comply <br />with Ta61e No. 17•A, Section 1706. Details <br />shou�d cicarly indicate this. <br />r <br />Structural members carrying masonry or con• <br />crete walls in buildings over one story in height <br />should he protected with minimum one�hour <br />, (i�e Dmtection. Section 1708. <br />Nonabsorbent tinish and backing for toilet room ' <br />walls and floor should conform with Section <br />1711 (a). <br />Shower stall watls should be tinished with a <br />herd, nonabsorbent surface to a height ot 6 <br />feat. Section 1711 (b). <br />� <br />Doors and panels oi shower and bathtub en• <br />closure should comply with Section 1711 (e) <br />to (g)• <br />Parapet walls not less than ................ inches in <br />height are required. °etlion 1709. <br />Eave overhangs and simitar architectural pro• <br />jeclions should comply with Section 1710. <br />28, Projections beyund the ezterior wall should con• <br />form with the least restrictive of the tollowing: <br />� (a) A point one•third the distance to the proper- <br />ty fine from an ezterior wail. Section 504 <br />" (b). <br />(b) A point one•third the distance irom an as• <br />sumed vertical plane tocated where tire• <br />resistive protection ot openin�s is first re• <br />quired due to location of property. Section <br />, 504 (b). <br />29."� Envclope ceili��s should satisfy the tollowing <br />� conditions [Seetion 43.i9 (6) 6.1: <br />-(a) Shouid not be used to provide (ire protec <br />tion bcam and girdcrs suppoAing more than <br />one tloor. <br />(b) Coluinns sliould be individually tire pro• <br />letted. <br />(c) Duct and outlet openin�s are limited to 100 <br />square inches in each ]00 square feet of <br />eeilinG area and sliould be protected with <br />npp�ovcA ;;�n dampers. <br />(d) Eleclrical outlet beces should be of steel <br />and not Crentcr ihan 1G square inches m <br />area. <br />30. Gypsum board ccilings in conjunction with tira <br />resislivc assemhlics shoitld Uc suppoited at <br />inlervals not ezceedin� 1G inches. Itein 27, <br />Tablc No. A3�C. <br />31 <br />33: <br />E� <br />36. <br />37. <br />38. <br />39. <br />40. <br />dl. <br />Wood stripping or suspended wood systems tor <br />gypsum board teilings should be nat less than <br />2•inch nominal thickness. Section 4704 (b). . <br />[Settion 4703 (b) tor wall stri�ping.7 <br />Final paAition layouts and dctails should be suD• <br />mitted prior to installation to iustify comNii• <br />�nce with occupancy, firrresistive, structural, <br />and e:it requirements. <br />Justitying test data in contorm�nce with Section <br />106 or an ICBO research recommendation is <br />required for ....................................................... <br />Rooms in which rubbish (linen) chules terminate <br />should De separeted from the remainder of the <br />6uilding with a one•hour occupancy separat(on. <br />Section 1706 (c). <br />Openings into ru6bish and linen chutes should <br />not be located in required exit corridors or <br />stairwavs. Section 1706 (cj. <br />SPECIAL OCCUPANCY REQUIREMENTS <br />6roup 6 <br />B•3 Oecupaneies should be of one�hour fire• <br />resisliva mnstruction if located in a basement <br />or above.the tirst story. Section 702 (b). <br />B•2 Oteupancies with an occupant Ioad of 1000 <br />or more should be in Type I, II, III one�hour. III <br />Heavy Timber or IV one�hour buildings. The <br />essemby room should not 6e in a basement <br />if it contains this high occupant load. Section <br />702 (b). <br />The mai� entrance shouid front directly upon or <br />have'a 20�foot wide access to a public way at <br />least 20 teet in wiAth. Section 703. <br />Light and ventilation should compty with Section <br />705. <br />A One•flour Fire-Resistive Occupancy Separation <br />�s required between the boilar or central heat• <br />ing plaM and the rest ol the building. Section <br />708. <br />Exterior openings for rooms containing a boiler <br />or central heating plant shouid be protected <br />with thrcc•fourths•hour tire�resislive assemblies <br />that are lixed, a�tomatic, or sclt�Qosing if lo• <br />cated below openings in another story or if less <br />than 30 (eet irom othcr doors or windows in <br />the same bui�diny. Section 708. <br />Gmup C <br />42.� Atmosphcric separetions should comply with <br />Section A02 (b). <br />43. <br />4M1. <br />45. <br />46. <br />47. <br />Sheet No. 2 of G Shects <br />Use ot rooms shouid bc cla-ified. Note th�t <br />rooms in Divisions i and 2 Occupancics used <br />fnr tlay eare purposes and rooms used tor <br />kindcrgarten, tirst, or second Cradc pupils and <br />Division 3 Occupancies cannol be localed <br />above the first story. Section 802 (c). <br />Special h�zard rooms sliould be separated irom <br />oil�cr porlions of tiic buildinG �Y ��ot Icss Lhan <br />a One�Hour Fire�Resistive Occupancy separa- <br />tion. Sedion 802 (d). <br />Onc requimd exit shoWd front directly upon, or <br />havc a 20400t widc aceess to, a PUUIic way at <br />least 20 lcet in width. Seclion NO3 (a). <br />Sanilary taeililics shoulA bc provi�led in aceord• <br />ance wilh Seclion 605. <br />I.i�,h[ and •�enlil�dion should comply with Seclion <br />805. <br />
The URL can be used to link to this page
Your browser does not support the video tag.