AUC-29-95 TUE 03:19 P19 INTERFACE. ENGINEERING 12068201628 P.02 <br />INTERFACE ENGINEERING, INC. Phone - (206) 820.1542 <br />12020 115th AVG. NE FOX - (206) 820-1628 <br />Kirkland, We. 98034 <br />Moves ' <br />TION <br />Project Name - SOUTHEAST MARINA Date - 829195 <br />Location- Everett WA <br />County - Snohomish <br />Architect- The BumgardnerArchitects By- RR <br />Washington nergy ode Requirements <br />Envelope <br />Component <br />U-Value <br />Area <br />F-Value Perimeter <br />UA <br />% <br />Roofs <br />0.036 <br />10,108 <br />- - <br />364 <br />8.5 <br />Walls <br />0.140 <br />10,214 <br />- - <br />1,430 <br />33.5 <br />Glazing <br />0.600 <br />3,571 <br />- . <br />2.143 <br />50.2 <br />Door <br />0.600 <br />112 <br />- - <br />67 <br />1.6 <br />Floor <br />- <br />0.54 496 <br />268 <br />6.3 <br />4,271 <br />-100.0 <br />UA Total - <br />r' F) <br />Proposed Construction <br />Envelope <br />Component <br />U-Value <br />Area <br />F-Value Perimeter <br />UA <br />i6 <br />Roof Type 1 <br />0.0497 <br />10,108 <br />- - <br />502.37 <br />12.611 <br />Wall Type 1 <br />0.116 <br />10,214 <br />- - <br />1184.8 <br />29.742 <br />Glazing Type 1 <br />0.55 <br />1,494 <br />- - <br />821.7 <br />20.627 <br />Glazing Type 2 <br />0.56 <br />2.077 <br />- - <br />1163.1 <br />29.197 <br />Door Type 1 <br />0.391 <br />112 <br />- . <br />43.792 <br />1.0993 <br />Floor <br />- <br />0.54 496 <br />267.64 <br />6.7235 <br />3983.6 <br />100 <br />GLAZING TYPE 2: SHADING COEFFICIENT= 0.57 <br />Column <br />Heading Units <br />U-Value Btu1(Hr'Sq.FL•Deg. F) <br />Area Sq.Ft. <br />F-Value Btu/(Hr-FCDeg. F) <br />Perimeter Ft <br />UA Btu/(Hr'Deg. F) <br />