My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1716 W MARINE VIEW DR BASE FILE 2018-01-02 MF Import
>
Address Records
>
W MARINE VIEW DR
>
1716
>
BASE FILE
>
1716 W MARINE VIEW DR BASE FILE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2022 10:52:08 AM
Creation date
2/27/2017 6:25:38 AM
Metadata
Fields
Template:
Address Document
Street Name
W MARINE VIEW DR
Street Number
1716
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
233
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Tl�t.—_'"'--199� 15:F' BUI')<,RRDNER (ARCH ?06 ,47 819.1 P-01 <br />THE To: <br />BIT)AIGAUDN EB, <br />ARCHITECTS <br />101 SILWARTS1art:r Attont:on: <br />SLIM Me <br />SEATILE WAS1WcfON <br />96101 <br />206713-1361 <br />FAk 2D"4741W <br />Project: <br />Copies. <br />SUBJECT: SECOND FLOOR FXiTLNIIG <br />CITY OF EVERI."17 <br />Jeff McFali <br />rat 106-239-8856 <br />Date: 27 Juty <br />AfAP,..," SIJPPI IF'; RiiTAT1. BVII DTNTTC- <br />Attached are two sets of proposals for exiting the second floor of the building. We need several <br />code interpretations. Please review the following questions and call me as soon as possible. <br />LXTER1OI: STAUMAY PROTECTION <br />-3306k allows unprotected openings adjacent to and under the stair since this is only a two story <br />building. This means that the retail space; on the first floor do not need to hive protecti,d <br />openings. <br />EXTI BALCONY PROTECTION <br />- 3305h requires protected doors and openings at the balcony if there is only one exit but not if <br />there are two. Is there any difference in the required protection between Schemes A and B? <br />- 3305j requires an elevator iobby in a corridor exiting over 30 occupants, however in our case the <br />elevator is not in the building and does not connect interior spaces. We are assuming that a lobby <br />is not required and the opening does not need protection per 3306k. <br />tiMOKE REMOVAL <br />- 3301a: Scheme A is open on two sides and seems to satisfy this requirement. Does Scheme B <br />create a need to remove the smoke by additional venting or is the one open side acceplahle.? <br />WI IEELCI1AIR, 12-VACLiAT1ON <br />- We are proposing to use the exit balcony as our evacuation area and the openings within 20 feet <br />(horizontally) are protected as shown. Please note that there are windows in the retail below, <br />however the balcony cow:fruction is non-combustible therefore we are not proposing to protect <br />the retail shorefront, <br />FROM - -- <br />�GHr.�! <br />Ml.1,1\110 <br />The8umgardncl..- o_cta <br />Pages, including this Page• - FAXFD,>n-�— `/ JARFDon: Pagel <br />
The URL can be used to link to this page
Your browser does not support the video tag.