My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2827 W MARINE VIEW DR 2016-01-01 MF Import
>
Address Records
>
W MARINE VIEW DR
>
2827
>
2827 W MARINE VIEW DR 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2017 9:56:08 AM
Creation date
2/27/2017 6:34:35 AM
Metadata
Fields
Template:
Address Document
Street Name
W MARINE VIEW DR
Street Number
2827
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
417
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
e <br />page 2 <br />8. The manual fire alarm system shall. be tested semi annually <br />and a log of such tests shall be readily accessable at the <br />manager's office. <br />9. The fuse in Lhe fuse box located on the third iloor north- <br />east side of building shall be propor.ly zeplaced with a <br />fusest-at with the proper amperage for the wire it serves. <br />10, The substandard electrical extension cord in the manager's <br />office must be removed. <br />11. Pioperly install a fire door with a une-hour £ire resistive <br />rating and insta7.l closing device to said door so door wi].7. <br />close completely for pmtection between tlie workshop area and <br />the managcr's office on the fir.st- floor level. <br />12. Remove in excess of one Gallon flammable liquids of any nature <br />from thi.s public assembly building on first floor shop area. <br />13. The furnace room located on the first floor shall be repaired <br />as follows: <br />a) The furnace room door shall be provided with anti-rebound <br />hardware or positive latching device and kept in the closed <br />positi�n at all times. <br />b) Proper ventilation for the complete combustion of the <br />furnace shall be provided. This access shall also be <br />provided with the proper fus:ible links and closers which <br />will seal off in the case of fire. <br />c) A one-hour fire reeistive material sha]1 bc extended <br />inside the furnace room as to seal up the windows on <br />the east side. As of to date, if a fire were to occur <br />in said room it would easily break through the window <br />and involve the fire escape immediately above it. <br />d) The plaster board now installed in thE: furnace room shall <br />have the seam properly taped. <br />14. The substandard electrical extension cord in the wozkshop ar.ea <br />must be removed. <br />15. Install and maintain an approved fire extinguisher(s) which <br />carry a minimum of a 2-A, 10-BC, U.L. rating ior protection <br />of the first floor workshop. <br />16. Properly extend the exhaust vent from the combustidn chamber <br />to the outside on space heater located in the north-east <br />corner of the workshop, first floor. <br />17. Discontinue the dangerous practice of storing tfie acetylene <br />cutting and �velding torch in the workshop of said apartmei.t <br />house. <br />
The URL can be used to link to this page
Your browser does not support the video tag.