Laserfiche WebLink
March 6, 20t3 <br />f.. <br />'UBL/C WOR/C5 <br />Jack Walklcy <br />Jack@Cobra.Construcfion.com <br />RE: Owner. 2902 W �larine Vie�•� Dr <br />]ob P.ddress: 2902 W Dlarine Vie�v Dr <br />P,an Check Nu: f31302-028 <br />Dear Mr. Walkley: <br />in response to your application for a construction permit, your plans have been examined and <br />you are advised that revisions may be necessary before � permit can be issued. Please review <br />and respond to the comments below. These comments address buildin9 issues only. Additional <br />r�visions, or additions, may be required by other departments (such as Utilities, Planning or <br />Fire). All references re;er to the 2009 International Building Code (IBC), the 2009 International <br />Fire Code (IFC), the 2009 International Mechanical Code (IMC), and the 2009 Washington State <br />Energy Code (WSEC), as amended by the State of Washington and adopted by the City of <br />Everett. The current IBC referenced standard for accessible design is the 2003 "Accessible and <br />Usable Buildings and Facilities" (ICC/ANSI A117.1). Federal ADA regulations and standards may <br />be more restrictive. <br />In order for the processing of your application to continue, it will be necessary to <br />provide the Building Division witli two complete new sets of construction <br />documents reflecting tlie corrections requested. <br />1. The scope of work for this submittal appears to be the ins.allation of a temporary job <br />shack, yet the submitted details and structural calculations only address the access <br />ramp. It appears that the ramp �vill be accessing a modified modular building above a <br />shipping storage container. Please provide a structural analysis and resulting design with <br />detailing lo sliow how the container and the modular building are to be supported. The <br />design must comply �vith chapter 16 of the IBC. <br />2. Apparently, the modular building lias been altered with an expansion of floor space. If <br />so, structural responsibility for the building will need to be assigned either through the <br />cerlification process at L� I, or by a new analysis and certification by the engineer of <br />record. <br />3. IE3C 1607.3 requires a design live load of 100 psf for all exits. The submitted ramp <br />desi9n is based on a live load of 40 psf. Please revise. <br />CITY OF EVERETT • 3200 Cedar Street • Everell, WA 98201 •(425) 257-8800 • Fax (425) 257-8882 <br />�„ � ,,.:.:•. ��� . ,�:-,.,�,�,,,�,.,�„��..: <br />