My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7353 RAINIER DR 2016-01-01 MF Import
>
Address Records
>
RAINIER DR
>
7353
>
7353 RAINIER DR 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/27/2017 8:23:48 AM
Creation date
2/27/2017 8:23:42 AM
Metadata
Fields
Template:
Address Document
Street Name
RAINIER DR
Street Number
7353
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� ' Vashington State Energy Code: Component Performance Worksheet C � -� ��� _ �5 � <br /> Zone 1, Other Fuels <br /> Project Name: Courtney Court Townhonies� Permit Appiicant: Shane Fortney <br /> Building C,Type N4, Unit:� � - Courtney Court, LLC <br /> Project Address: Rainier Dr Address: 15720 Main St,Suite 210 <br /> Everett,WA Mill L'reek,WA 98012 <br /> Form prepared by: R Scott Dorough Phr,ne: 425•357•0286; <br /> DRS Energy Manayement Email: sfnrtney@sbtproperties.ccm <br /> 1001 W Toledo, Bellingham,WA 58229 <br /> 360-671-9390 Jurisdiction: City ot Everett,WA <br /> Heating System Size <br /> Ducis are located in unconditioned space.0 <br /> Conditioned Floor Area 7822 Equipment size over design load iso% • <br /> Conditioned Building Volume 16300 Btu/hour output 28,106 <br /> Weather Stalion 'evcren aaine nFe _ � KW 82 <br /> Component Perfarmance,Zone 1, Other: Code Target Values Proposed Design Values <br /> U-Factor Area UA Area UA <br /> Vertical Giazing 0.40C 273 109.3 2t 1 84.4 <br /> Overhead Glaziny Insfalled in Attics 0.580 0 0.0 0 0.0 <br /> Overhead Glazing Insfalled in Vaulfs 0.580 0 0.0 0 0.0 <br /> Doors 0.200 40 8.0 40 32 <br /> Attics 0.031 762 23.6 762 19.8 <br /> Single RaftedJoist Vault 0.03" u 0.0 0 0.0 <br /> Wall (above g�ade) 0.062 938 58.1 1000 57.0 <br /> Floors 0.029 445 12.9 445 13.9 <br /> Slab 0.540 40 21.6 40 28.0 <br /> Below Grade l�iterior <br /> 2'depth,wall 0.043 0 0.0 0 0.0 <br /> 2'depth, slab 0.690 0 0.0 0 0.0 <br /> 3.5'depth,wall O.Owt 0 0.0 0 0.0 <br /> 3.5'dep?n, slab 0.640 0 0.0 0 0.0 <br /> 7'den;h,wall 0.037 0 0.0 0 0.0 <br /> 7'deplh, �lab 0.570 0 0.0 0 0.0 <br /> [3elow Grade Ezterior <br /> 2'depth,wall 0.070 0 0.0 0 0.0 <br /> 2'depth, slab 0.600 0 0.0 0 0.0 <br /> 3.5'depth,wall 0.064 0 0.0 0 0.(1 <br /> 3.5'deplh,slab 0.570 0 0.0 0 0.0 <br /> 7'depth,wall 0.056 0 0.0 0 C � <br /> 7'depth, slab 0.420 0 0.0 0 0.0 <br /> Target UA Total 233.6 Proposed UA Total 206.4 <br /> II;he Proposed UA s The Target!he UA requirements are meet. <br /> Check other code requirert�enis <br /> Copyright 2002, WSUCEEP OZ-088 (Version 4) <br /> Copied by permission from Washington State University Cooperative Extension Energy Program. <br /> (see copyright restrictions) <br /> 4/17/2007 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.