My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7355 RAINIER DR 2016-01-01 MF Import
>
Address Records
>
RAINIER DR
>
7355
>
7355 RAINIER DR 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/27/2017 8:24:36 AM
Creation date
2/27/2017 8:24:29 AM
Metadata
Fields
Template:
Address Document
Street Name
RAINIER DR
Street Number
7355
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Washington State Energy Code: Cemfonent Pertormance VVorksheet L G1 v��- G�i 7 <br /> Zone 1, Other Fuels <br /> Project Name: Counney Court Townhomes Permit Applicant: Shan� Fortney <br /> Building C, Type q3, Uni4� �•; Courtney Court, LLC <br /> Project AJdress: Rainier Dr Address: 15720 Main St, Suite 210 <br /> Everett, WA Mill Creek,WA 98012 <br /> Form prepa�^d by: R Scott Dorough Phone: 42;,-357-0286; <br /> DR,, cnergy Management Email: sfortneyiasbiproperties.com <br /> 1001 W Toledo, Bellinghem,WA 98229 <br /> 360-671-9390 Jurisdiction: Cilyof Everett, WA <br /> Heeting System Size <br /> Ducts are located in unconditi,,ned space.� <br /> Conditioned Floor Area 1822 Equipment eize over design load�l5o% � <br /> Conditioned Building Volume _ 16300 Btu/hou output 28,375 <br /> Weather Station everett Paine nt� __ __ _� KW 8.3 <br /> Comp:+nent Perlormance,Zone 1, Other: Code Target Values Proposed Desfgn Values <br /> U•Factor �ea UA Area UA <br /> Vertical Glazing 0.400 273 109.3 211 84.4 <br /> Overhead Glazing Installed in Attics 0.580 0 0.0 0 u.0 <br /> Overhead Glazing lnstalled in Vaults 0.580 0 0.0 0 0.0 <br /> Doors 0.200 40 8.0 40 3.2 <br /> Attics 0.037 741 23.0 741 19.3 <br /> Si igle RaftedJoist Vault 0.034 21 0.7 21 D.G <br /> Wall (above grade) 0.062 1002 62.1 1064 60.6 <br /> Floors 0.029 445 12.9 445 13.9 <br /> Slab 0.540 40 21.6 40 28.0 <br /> Below Grade Inierior <br /> 2'depth, wall 0.043 0 0.0 0 0.0 <br /> 2'depth slab 0.690 0 0.0 0 0.0 <br /> 3.5'depth, wall 0.041 0 0.0 0 0.0 <br /> 3.5'depth, slab 0.640 0 0.0 0 0.0 <br /> 7'depth,wall U.C97 0 0.0 0 0.0 <br /> 7'depth, siab 0.570 0 0.0 0 0.0 <br /> Below Grade Exterior <br /> �'depth,wall 0.070 0 0.0 0 0.0 <br /> 2'depth, slab 0.600 0 0.0 0 0.0 <br /> ?.5'depih,wall 0.064 0 0.0 0 0.0 <br /> 3.5'deptli, siab 0.570 0 0.0 0 0.0 <br /> 7'depih,wall 0.050 0 0.0 0 0.0 <br /> 7'depth, slab 0.420 0 0.0 0 0.0 <br /> Target UA Total 237.6 Proposed UA Totdl 2t G J <br /> It Ihe �i�posed UA 5 The Target ihe UA requirements are meel. <br /> Check other code requirem�nts <br /> Copyright 2002, \NSUCEEP C2-088 (Version 4) <br /> Cupied h�permission from Washington State Universiry Cooperetive Extension Energy Program. <br /> (see copyrighl restrictions) <br /> 4/17/2007 1 ot 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.