April 20, 1976 <br /> fhe Ever��ac:; <br /> crcr oF <br /> everett � <br /> CITY HALL • S59�B945 , <br /> [V[IIRT� WAlHINGTON ' <br /> 9l10t � <br /> III{�LCTION O[�AMTM[NT <br /> Hr. Gerald Brothers <br /> 1717 Vernon Road <br /> Everett, Washington 98205 <br /> Reference: 15 Unit Apartment Building <br /> 7332 Rainier D�ive <br /> Fire Zone 3 <br /> Type V - 1 hour Canstruction <br /> Occupancy Group H <br /> Occupant Load 68 <br /> Plan Check No. 76-213 <br /> Dear Mr. Brothers: <br /> The plans as resubmitted for the referenced project <br /> have been reviewed and thc following items as outlined <br /> in my correction letter have not been corrected. <br /> Item No. z: <br /> �_p board ceilings in conjuction with fire- <br /> resistive construction should be supported at <br /> intervals not exceeding 16" . Item 27 Table 43-c. <br /> (Several �ypsum i3oard l4anufacturers have I:C.B.O. <br /> approva.l for 24" SuoForts. ) <br /> Itam No. 3: . <br /> Floor ceiling and roof ceiling assemblies shall <br /> comply with Table 43-c. <br /> Item Mo. 6 : � <br /> Ventilation for laundry room shall be provided in <br /> accordance with Section 1305 (a) . <br />