Laserfiche WebLink
Dutch Bros. Coffee Stormwater Site Plan Everett, Washington <br /> CITY OF EVERETT STORMWATER MANAGEMENT MANUAL <br /> Detention Ponds <br /> Date <br /> Drainage <br /> System Maintenance Activities and Conditions That <br /> Frequency Feature 1 1 1 1 Problem Conditions to Check For Should Exist <br /> M,S General Trash and Debris Any trash and debris which exceed 5 cubic Trash and debris cleared from site_ <br /> feet pert,404 square feet(this is about equal <br /> to the amount of trash it would take to fill up <br /> one 32 gallon garbage can).In general,there <br /> should be no visual evidence of dumping.If <br /> less than threshold all trash and debris will be <br /> removed as part of next scheduled <br /> maintenance_ <br /> A General Poisonous Any poisonous or nuisance vegetation which No danger of poisonous vegetation where <br /> Vegetation and may constitute a hazard to maintenance maintenance personnel or the public might <br /> noxious weeds personnel or the public.Any evidence of normally be_(Coordinate with the Snohomish <br /> noxious weeds as defined in the Snohomish County Health Department)Complete <br /> County Noxious Weeds fist. Apply eradication of noxious weeds may not be <br /> requirements of adopted integrated pest possible_Compliance with state or local <br /> management policies for the use of herbicides. eradication policies required <br /> M,S General Contaminants and Any evidence of oil.gasoline,contaminants or No contaminants or pollutants present <br /> Pollution other pollutants (Coordinate removal/cleanup with the City of <br /> Everett Surface Water Management 425-257- <br /> 8885 and/or DOE Spilt Response 845-424- <br /> 8802.) <br /> M General Rodent Holes If the facility is constructed with a dam or berm, Rodents removed and dam or berm repaired. <br /> took for rodent holes or any evidence of water (Coarthnate with Snohomish County Health <br /> piping through the dam or berm_ Department coordinate with Ecology Darn <br /> Safety Office if pond exceeds 10 acre-feet_) <br /> Ht General Seaver Dams Beaver darn results in an adverse change in Facility is returned to design function.Contact <br /> the functioning of the facility. the Washington Department of Fish and <br /> Wildlife to coordinate with a Nuisance Wildlife <br /> Control Operator. <br /> A General Insects When insects such as wasps and hornets Insects destroyed or removed from site.Apply <br /> interfere with maintenance actsrffies. insecticides in compliance with adopted <br /> integrated pest management policies. <br /> Date <br /> Drainage <br /> System Maintenance Activities and Conditions That <br /> Frequency Feature 1 1 1 1 Problem Conditions to Check For Should Exist <br /> A General Tree Growth and Tree growth and dense vegetation which Trees and vegetation that does not hinder <br /> Dense Vegetation impedes inspection,maintenance access or inspection or Maintenance activities. <br /> interferes with maintenance activity(i.e.,slope Harvested trees should be recycled into mulch <br /> mowing,silt removal,vectoring,or equipment or other beneficial uses(e.g.,alders for <br /> movements). firewood)_ <br /> A General Hazard Trees If dead,diseased,or dying trees are identfied Remove hazard trees <br /> (Use a certified Arborist to determine health of <br /> tree or removal requirements) <br /> S General Performance Check crest gauge against design Record reading. Notify City if not meeting <br /> expectations(see maintenance plan) design performance. <br /> M Side Erosion Erosion damage aver 2 inches deep where Slopes should be stabilized using appropriate <br /> Slopes of cause of damage is still present or where there erosion control measure(s);e.g.,rack <br /> Pond is potential far continued erosion. reinforcement_planting of grass,compaction. <br /> M.S Side Erosion Any erosion observed on a compacted berm If erosion is occurring on compacted berms a <br /> Slopes of embankment licensed civil engineer should be consulted to <br /> Pond resolve source of erosion. <br /> bT Storage Sediment Accumulated sediment that exceeds 14 Sediment cleaned out to designed pond shape <br /> Area percent of the designed pond depth unless and depth:pond reseeded if necessary to <br /> otherwise specified or affects inletting or control erosion_ (If sediment contamination is <br /> outletting condition of the facility. a potential problem.sediment should be tested <br /> regularly to determine leaching potential prior <br /> to disposal.) <br /> M Storage Liner(lf Applicable) Liner is visible and has more than three one- Liner repaired or replaced.liner is fray <br /> Area fourth inch holes in it covered. <br /> A Pond Settlements Any part of berm which has settled 4 inches Dike is built back to the design elevation. <br /> Berms lower than the design elevation.if settlement is <br /> (Dikes) apparent,measure berm to determine amount <br /> of settlement Settling can be an indication of <br /> more severe problems with the berm or outlet <br /> works.A licensed civil engineer should be <br /> consulted to determine the source of the <br /> settlement <br /> nArl roll/ n.,. IC <br />