Laserfiche WebLink
Component Perform.__ .+e Path, pg. 1 Zor._ ,s 4c/5b ENV-UA <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Oct 2013 <br /> Project Address 2202 Broadway Date 01/12/2016 <br /> Occupancy Group ® Commercial 0 Group R For Building Department Use <br /> Change in occupancy or space conditioning 0 <br /> Note-Proposed UA may exceed Target UA by 10%per C101.4.4 and C101.4.5 <br /> Fenestration Area as%gross above-grade wall area 9.2% Max.Target: 30.0% <br /> Skylight Area as%gross roof area 0.0% Max.Target: 5.0% <br /> Vertical Fenestration Alternates: None Selected on ENV-SUM <br /> Notes: 1:If vertical fenestration or skylight area exceeds maximum allowed per C402.3.1, then Target Area Adjustment of all applicable envelope <br /> elements will be calculated by the compliance form. Refer to Target Area Adjustments worksheet for this calculation. <br /> 2:U-factors shall come from Appendix A, Chapter C303, or calculated per approved method as specified in C402.1.2. <br /> Building Component Proposed UA Target UA <br /> Provide source of U-factor, page/plan#of assembly detail&ID U-factor x Area(A) =UA(U x A; U-factor x Area(A)= UA(U x A) <br /> R= ID: 0.034 <br /> a) R= ID: Above Deck Insulation U-0.034 <br /> 0 <br /> R= ID: <br /> N -o R= ID: 0.031 <br /> 8 m R= ID: Metal Building U-0.031 <br /> R= ID: <br /> R=38 ID: 0.026 480 12.6 0.021 480 I 10.1 <br /> Zr) R= ID: Single raft,attic,other U-0.021 <br /> O R= ID: <br /> R= ID: 0.055 <br /> LL- R= ID: Steel/metal frame U-0.055 <br /> 2 R= ID: <br /> m <br /> s -o R= ID: 0.052 <br /> Q m R= ID: Metal Building U-0.052 <br /> N R= ID: <br /> • R=19 ID: 0.053 1324 69.7 0.054 1324 71.5 <br /> S o R= ID: Wood Frame,other U-0.054 <br /> o <br /> Q R= ID: <br /> 0 <br /> « R= ID: 0.104 <br /> co <br /> m R= ID: Mass Wall U-0.104 <br /> R= ID: <br /> 0 R= ID: 0.104 <br /> To <br /> o R= ID: Assumed to be Mass Wall U-0.104 <br /> m LI R= ID: <br /> C7 R= ID: <br /> R= ID: 0.031 <br /> co R= ID: Mass Floor U-0.031 <br /> N`o R= ID: <br /> o• -o R= ID: 0.029 <br /> o <br /> g R= ID: Joist/Framing U-0.029 <br /> LL R= ID: <br /> F-factor x Perimeter =UA(U x A) F-factor x Perimeter= UA(U x A) <br /> R=10 ID: 0.540 92 49.7 0.540 92 49.7 <br /> mSlab-On-Grade U-0.54 <br /> m -c R = ID: <br /> c• R= ID: <br /> o <br /> 0 R= ID: 0.550 <br /> co `(75 , R= <br /> aID: Heated Slab-On-Grade U-0.55 <br /> = R= ID: <br /> `Proposed non-residential CMU walls meeting Table C402.1.2 Area t UA 1 Area UA <br /> Footnote D requirements can use the target U-value of 0.104 rather Page 1 <br /> than Appendix A values.Show footnote requirements in plans. Subtotal 1896 132 1896 131 <br /> Component Performance Compliance (UA) UA COMPLIES <br />