My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2202 BROADWAY DUTCH BROS COFFEE 2017-04-05
>
Address Records
>
BROADWAY
>
2202
>
DUTCH BROS COFFEE
>
2202 BROADWAY DUTCH BROS COFFEE 2017-04-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/5/2017 2:45:26 PM
Creation date
2/27/2017 8:28:23 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
2202
Tenant Name
DUTCH BROS COFFEE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHGC Calculation Zones 4( b ENV-SHGC <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Oct 2013 <br /> Project Address 2202 Broadway Date 01/12/2016 <br /> 9.2% Max.Tar et: 30% For Building Department Use <br /> Fenestration Area as%gross above-grade wall area9 <br /> Skylight Area as%gross roof area Max. Target: 5% <br /> Vertical Fenestration Alternates: None Selected on ENV-SUM <br /> Notes: 1-Proposed vertical fenestration and skylight areas entered in ENV-SHGC must match proposed <br /> fenestration areas in ENV-UA. <br /> 2-If Target Area Adjustment is required per ENV-UA,then target areas will be automatically <br /> adjusted in ENV-SHGC. Refer to Target Area Adjustments worksheet for this calculation. <br /> 3-Provide NFRC rated SHGC or default from Table C303.1.3(3)for fenestration assembly SHGC. <br /> 4-Fenestration that separates conditioned space from a non-conditioned or semi-conditioned <br /> space shall be included in this worksheet. <br /> Skylights Proposed SHGC Target SHGC <br /> Provide source of SHGC, page/plan#of assembly detail&ID SHGC x Area(A) =SHGC x A SHGC x Area(A)= SHGC x A <br /> ID: 0.35 <br /> ID: SHGC 0.35 <br /> ID: <br /> ID: <br /> ID: <br /> Totals Totals <br /> All Non-North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> Provide source of SHGC,page/plan#of assembly PF <br /> PF SHGC* x Area(A)=SHGC x A SHGC x Area(A)= SHGC x A <br /> detail&ID Category <br /> ID: 0 0.40 129 51 PF<0.2 0.40 129 51.5 <br /> ID: 0 0.2<_PF<0.5 0.48 <br /> ID: 0 PF>_0.5 0.64 <br /> ID: 0 ++If projection factor(PF)credits are <br /> ID: 0 applied to the proposed design, Target <br /> ID: 0 SHGC will sum fenestration area by PF <br /> 0 <br /> category. <br /> ID: <br /> ID: 0 <br /> ID: 0 <br /> ID: 0 <br /> +If projection factor credit is applied, then vertical Totals 128.7 51.5 Totals 128.7 51.5 <br /> fenestration must be entered in the correct table according to <br /> orientation. If credit is not applied then all vertical <br /> fenestration can be entered in either table. <br /> *Note:Fenestration that separates conditioned space from a <br /> non-conditioned or semi-conditioned space shall be listed <br /> here with a proposed SHGC equal to the target value. <br /> North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> Provide source of SHGC,page/plan#of assemblyPF SHGC* x Area(A)=SHGC x A PF SHGC x Area(A)= SHGC x A <br /> detail&ID Category <br /> ID: 0 0.40 7 3 PF<0.2 0.40 7 2.9 <br /> ID: 0 0.25PF<0.5 0.44 <br /> ID: 0 PF>_0.5 0.48 <br /> ID: 0 ++If projection factor(PF)credits are applied <br /> ID: 0 to the proposed design, Target SHGC will <br /> ID: 0 sum fenestration area by PF category. <br /> ID: 0 <br /> North Total 7.3 2.9 7.3 2.9 <br /> Area SHGC x A Area SHGC x A <br /> To comply, the Proposed total SHGC x A for all fenestration(vertical Grand Grand <br /> &skylights)shall not exceed the Target total SHGC x A. Total 136.0 54.4 Total 136.0 54.4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.