Laserfiche WebLink
SHGC Calculation Zones 4( b ENV-SHGC <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Oct 2013 <br /> Project Address 2202 Broadway Date 01/12/2016 <br /> 9.2% Max.Tar et: 30% For Building Department Use <br /> Fenestration Area as%gross above-grade wall area9 <br /> Skylight Area as%gross roof area Max. Target: 5% <br /> Vertical Fenestration Alternates: None Selected on ENV-SUM <br /> Notes: 1-Proposed vertical fenestration and skylight areas entered in ENV-SHGC must match proposed <br /> fenestration areas in ENV-UA. <br /> 2-If Target Area Adjustment is required per ENV-UA,then target areas will be automatically <br /> adjusted in ENV-SHGC. Refer to Target Area Adjustments worksheet for this calculation. <br /> 3-Provide NFRC rated SHGC or default from Table C303.1.3(3)for fenestration assembly SHGC. <br /> 4-Fenestration that separates conditioned space from a non-conditioned or semi-conditioned <br /> space shall be included in this worksheet. <br /> Skylights Proposed SHGC Target SHGC <br /> Provide source of SHGC, page/plan#of assembly detail&ID SHGC x Area(A) =SHGC x A SHGC x Area(A)= SHGC x A <br /> ID: 0.35 <br /> ID: SHGC 0.35 <br /> ID: <br /> ID: <br /> ID: <br /> Totals Totals <br /> All Non-North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> Provide source of SHGC,page/plan#of assembly PF <br /> PF SHGC* x Area(A)=SHGC x A SHGC x Area(A)= SHGC x A <br /> detail&ID Category <br /> ID: 0 0.40 129 51 PF<0.2 0.40 129 51.5 <br /> ID: 0 0.2<_PF<0.5 0.48 <br /> ID: 0 PF>_0.5 0.64 <br /> ID: 0 ++If projection factor(PF)credits are <br /> ID: 0 applied to the proposed design, Target <br /> ID: 0 SHGC will sum fenestration area by PF <br /> 0 <br /> category. <br /> ID: <br /> ID: 0 <br /> ID: 0 <br /> ID: 0 <br /> +If projection factor credit is applied, then vertical Totals 128.7 51.5 Totals 128.7 51.5 <br /> fenestration must be entered in the correct table according to <br /> orientation. If credit is not applied then all vertical <br /> fenestration can be entered in either table. <br /> *Note:Fenestration that separates conditioned space from a <br /> non-conditioned or semi-conditioned space shall be listed <br /> here with a proposed SHGC equal to the target value. <br /> North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> Provide source of SHGC,page/plan#of assemblyPF SHGC* x Area(A)=SHGC x A PF SHGC x Area(A)= SHGC x A <br /> detail&ID Category <br /> ID: 0 0.40 7 3 PF<0.2 0.40 7 2.9 <br /> ID: 0 0.25PF<0.5 0.44 <br /> ID: 0 PF>_0.5 0.48 <br /> ID: 0 ++If projection factor(PF)credits are applied <br /> ID: 0 to the proposed design, Target SHGC will <br /> ID: 0 sum fenestration area by PF category. <br /> ID: 0 <br /> North Total 7.3 2.9 7.3 2.9 <br /> Area SHGC x A Area SHGC x A <br /> To comply, the Proposed total SHGC x A for all fenestration(vertical Grand Grand <br /> &skylights)shall not exceed the Target total SHGC x A. Total 136.0 54.4 Total 136.0 54.4 <br />