Laserfiche WebLink
� C�� <br /> '3 <br /> C H <br /> 9HCn <br /> 4 <br /> y i-�i <br /> FC C] <br /> H 70 <br /> � H � <br /> VJ H � <br /> y $'sy-•':•�. ..r,q»- . <br /> � � � �`'.. .� pl/BL/C L�YO � : <br /> O H y�"' <br /> � �g ::.<.:. <br /> �r n <br /> H <br /> � y� October 12, 1992 <br /> d H ; <br /> � e� <br /> � t� � Van Rossen Construction <br /> 2526 Baker Avenue <br /> y o y Everett, Washington 98201 • <br /> RE: Owner: Jim Conery <br /> Job Address: 443?. Rid;emont Drive <br /> Plan Check No.: 38005 <br /> L�ear Mr. Van Rossen: <br /> In response to your applicacion for a construction permit, your plans have been exami�,ed and you are <br /> advised that the issuance of a permit is being;withheld for the teasons listed below. Thece comments <br /> address building issues only, additional revisions or additions may be required by other departments <br /> (such as Utilities, Planning or Fire). All references refer to the 1988 Uniform Building Code and/or <br /> Washington State Energy Code unless stated otherwise. <br /> � ' 1. Typical wall section does not show how roof is constructed. Show all components of roof <br /> t ' structure, insuladon, "cover board" etc.. <br /> '�1 2. Show how 4x8 beam, in crawl space, is supported at both ends. Show concrete pads under posts. <br /> � ' 3. ShoH� how 2x8 floor joists adjacent ro masonry fireplace are suppoRed. Joists may not be <br /> � supported by fireplace. <br /> � 4. Provide roof framing plan. Show all beams and posts, including ridge beam. Show framing <br /> ' azound fireplace. <br /> `_1 5. Specify Fwsdbeam, beam/beam and post footing connections. Be specific. <br /> � 6. Smoke detectors shall be installed in the azea or corridor giving access to each separate area used <br /> for sleeping and in each sleeping room. A smoke detector shall be mstalled on each level. Smoke <br /> '�' detectors shall emit a signal when batteries are low. <br /> 0�� In order for ehe yrocessing of your application to continue, it will be necessary to provide the Building <br /> Department with two copies of drawings reflecting the corrections requested. <br /> '�1 Upon re-submitta! of the drawings, your application �vill be given priority and plan review <br /> ��� recommence. <br /> All reouired submitl�ls shall be of sufficient detail and contain sufficient in(ormation ro ensure that the <br /> proposed strucwre will be constructed in complia�ice with all adopted codes. <br /> Sincerely, <br /> Jeff Heilman <br /> Engineering Technician <br /> n1:<s�p�u,<t•: <br /> CITY OF EVERETT• 3200 Cedar Streel • Everett, WA 98201 • (206) 259-8800 • Fax (206) 259-8882 <br />