Laserfiche WebLink
WATTSUN65@3n c 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/26/93 <br /> FILE: C:\WATTSUNS\WSFILES\0593022.WS HOUSE ID: ADDITION <br /> Infiltration isStandatd Air Sealing ACH 0.350 6768ft3 ( 42.2) <br /> _____""__""_______"'__' <br /> Proposed UA 128 <br /> Struc Mass Light Frame, Sheetrock walls M- 3.000 688 2064 <br /> '-'---------------------------------------'----------------'---------------'---- <br /> HEATING/COOLING/VENTILATING SYSTElIS <br /> PROPOSED <br /> Heating System Type: Electric: Zoned <br /> systam Efficiency: 100 $ <br /> Modified Efficiency: l00 $ <br /> Design ACH: 0.60 <br /> Heating Load(at 50F dt) : 9997 Btu/hr <br /> System Size: 2.9 kW <br /> Maximum Size @150t: 4.4 kW <br /> Average Annual Heat: 1696 kWh <br /> Annual Cost: $ 75 <br /> Ventilation System: Inteqrated Spot <br /> & Whole House <br /> Coolinq System: <br /> SEER: 0.0 (Unducted) <br /> Cooling Load(at OF dt) : 14942 Btu/hr <br /> Recommended Size @125$: 1.7 tons <br /> Annual cool requirement: *** kWh/yr <br /> Solar Access: Partially Shaded <br /> -'--'-----------'----'--'-------------'--"------------'------------------------ <br /> GLAZING ORIENTATION <br /> PROPOSF.D PROPOSED <br /> South . 45.5ft2 North . 45.Sft2 <br /> Southeast : Northwest : <br /> East . 45.5 West . 45.5 <br /> Northeast : Southwest : <br /> ------'----------'--"---------------------------------------------------------- <br /> Economic and energy concumption estimates are designed for comparative <br /> purpoaes only. Actual cost for heating will vary depending on weather <br /> conditions, occupant lifestyle and other factors. <br />