Laserfiche WebLink
C160 1 - c17-- <br /> s / rtaA,1(4ti 3 <br /> BDT BLOWER DOOR TEO RESULTS <br /> Blower Boor Testing NW 425-312-3914 <br /> BlowerpoorNW.com <br /> Job Completed By <br /> Technician Name frR,g_A( \01/q_60 Date: /6)/ ./PC)/ <br /> Job Site Information <br /> Permit#: <br /> Address and Lot Number: 1-S71 & iw cutsty ; 407-3 <br /> City: � �' '� Zip Code: ` 'T,A d- <br /> Cond.Floor Area(ft2): ,‘4//0 D Age of House: /VEGt) <br /> Source(check one): Plans U Estimated U Measured <br /> Test Results <br /> Puss U Fail ❑Could Not Complete / (6' ACH50 <br /> CFMQ50Pa <br /> Ring(check one if applicable): U Open U A I03 ❑C <br /> o <br /> Blower Door Fan Location: R/)/y% PODt°--- Weather Conditions: Rd9-/A/ — 7 <br /> Results shall be reported as Air Changes per Hour at 50 Pascals(ACH50)and shall be calculated as follows: <br /> ACH50=(CFM50 x 60)/Volume <br /> Where: <br /> CFM50=Blower door fan flow at 50 Pascal pressure difference <br /> Volume=Conditioned Floor Area of the housing unit x ceiling height <br /> 2015 Washington State Energy Code reference: <br /> R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour.Testing shall be conducted with a blower <br /> door at a pressure of 02 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by as approved third patty.A written report of the results of the test shall <br /> be signed by the party conducting the test and provided to the code offices' Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.Once <br /> visual inspection has confirmed sealing(see Table R402.4.1.1),operable windows and doors manufactured by small business shall be permitted to be sealed off at the frame prior to the test. <br /> During testing. <br /> 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measuring <br /> 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measu r <br /> 3.Interior doors,if installed at the time of the test,shall beopen,access hatches to conditioned crawl spaces and conditioned attics shall be open; <br /> 4.Exterior openings for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; <br /> 5.Heating and cooling systems,if installed at the time of the test,shall be turned oft and <br /> 6.Supply and return registers,if installed at the time of the test,shall be hilly open. <br />