Laserfiche WebLink
i <br /> d <br /> 11.Record the flow rate (with simple manometers, the fan pressure (Pa) is ! <br /> converted to CFMSo using a flow table. Many digital manometers sold with <br /> blower doors can automatically perform this conversion, and display <br /> CFMSo directly.) Consult your blower door and manometer manuals. <br /> You now must convert the flow rate (CFM50) to SLA. Use the following formula: <br /> SLA = (CFM50 X .055) /(CFA X 144) <br /> Where: SLA = Specific Leakage Area <br /> CFM50 X .055 = Blower door fan flow rate at 50 pascal pressure <br /> difference, converted to a conversion factor(SLA reference <br /> pressure) <br /> CFA x 144 = Conditioned floor area of the housing unit, converted <br /> to square inches <br /> Example: A blower door test has been done on a 2,000 square foot house <br /> and the fan flow (CFM50) rate is 1100 CFM. <br /> SLA = (CFM50 X .055) /(CFA X 144) <br /> SLA = (1100 X .055) / (2000 X 144) <br /> SLA = 60.5 / 288,000 <br /> SLA = .00021 <br /> Since the code requires the SLA to be less th3n .00030, this house complies with <br /> an SLA of .00021. Record the SLA on the energy certificate on or near the <br /> electrical panel. <br /> (s7 2010 Washington Statc Univcr:•ity I�xtension Bncrgy Program.ll�is publica�ion contains malcrial wriltcu <br /> and procluced for public dislribution. Pemiission to copy or diaseminate:dl or pa�t of this mt+tcrial is <br /> grml��cl, provid��cl dtul�he copies are not made or distributed (or commercial ndvanlage,and that each is <br /> rcfcrencccl by tiilc wilh crcdit io Ilic Washingion Stale University Lslension Encrgy Program. Copying. <br /> rep�intin,� or disscininatinn,cl�v:iranic rn�olhcnvise, li�r any olher use reyuir�.<prior writle,7i pemiission <br /> finm ihc \O�ashing�nn titate Univcrsily I:xtcnsinn lincrgy Prugram. \VSUI3I:PIU-001 Rcv. I. 2010 <br /> _ ; <br /> _ <br />