My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8316 RIM DR 2018-01-02 MF Import
>
Address Records
>
RIM DR
>
8316
>
8316 RIM DR 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2022 8:25:13 AM
Creation date
2/27/2017 9:25:15 AM
Metadata
Fields
Template:
Address Document
Street Name
RIM DR
Street Number
8316
Notes
PART OF SHORT PLAT 1202-1993-32
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> Duct l.eakage Aflidavit <br /> Permit#: �� ���t� - 06 S <br /> House address or lot number: �3 /6 K iltl U r <br /> city: Fv � ��ff zip: � 8 2 Do' <br /> Cond. Floor Area(ft2): Z� Source(circle one): Plans Estimated Measured <br /> ❑ Duct tightness testing is not required for this residence per exceptions listed at the end of this document <br /> Air Handler in conditioned space? ❑Yes � no Air Handler present during test?�yes� no <br /> Circle Test Method: Leakage to Outside Total Leakage <br /> Maxfmum duct leakage: <br /> Post Construction,total duct leakage: (floor area x .OB)= Z SF' CFM@25 Pa <br /> Post Construction, leakage to outdoors: (iloor area x.O6) = CFM@25 Pa <br /> Rough-In,total duct leakage with air handler installed: (floor area x .06) = CFM@25 Pa <br /> Rough-In,total duct leakage with air handler not installed: (floor area x.04) = CFM@25 Pa <br /> Test Result: `� S CFM@25Pa <br /> Ring (circle one if applicable): Open 1 2 3 <br /> Duct Tester Location: ���-�►4 � �2 �-t'� �� Pressure Tap Location: //7�C� ��t �f/�� <br /> C <br /> I certity that these duct leakage rates are accurate and determined using standard duct testing protocol. <br /> �I�2f'sry So��c1;i•it V / <br /> Company Name: Ht,�f i n� w�c� ���/�'�`� �n C Technician: U`/��o2 I� i`� 5�`�1t l�a <br /> a. =_' <br /> Technician Signature: `rr � ��`'� ,Date: 3 Z� �z Phone Number: �yZ�� ��� "'�-��� <br /> Wanhington State Energy Code reference: <br /> 503.10.�Sealing.All ducts,air handlers,filter boxes,and building cavities used es ducts shall be sealed.Joints and seams shall comply <br /> vnth Seclion M1601.3 01 the Intemational Residenfial Code or 603.9 0l the intemafional Mechanical Code. Ducl tightness testing shall be <br /> conducted lo veny Ihal Ihe duds are sealed.A signed aKdavit documenting the test results shall be provided lo the jurisdidion having <br /> authonly by Ihe lesting agenl.When required by the buildinc�oKdal,the test shall be conducted in the presence of department slall. <br /> Exceptions: 1.Duci tighlness lest is nol required if Ihe air handler and all duqs are localed wilhin conditioned space. <br /> 2.Duct testing is nol required if Ihe fumace is a�ondired venl rype com6ustion appliance installed in an unconditioned space. <br /> A maximum of six feet of connecled duchwftc in Ihe unconditioned space is allowed.All additionat supply and retum duds <br /> shall be vnihin Ihe conditioned space.Ducts outside the conditioned space shail be seaied vAth a maslic type dud sealent and <br /> insulated on Ihe ezferior wilh R-8 insulation for above grade ducts and R•5 water resislant insulation when within a slab or <br /> eahh. <br />
The URL can be used to link to this page
Your browser does not support the video tag.