Laserfiche WebLink
'1 .� I <br /> I <br /> Plan Chxk No. 51054 <br /> March 26, 1996 <br /> Page 2 of 2 <br /> 7. Provide minimum 36" landing not more than 8" below the finished fluor at all extaior <br /> entrancr/exits. Show on plans. <br /> 8. Provide cross �ection through covered poc+ch. Show all components. <br /> 9. Provide handrail per Secdon 1006.9 UBC. Show rcquiiements on stair detail. <br /> 10. Saxion M stwws 4x4 D.F. A'2 beam; the foundadon pian c�lls out 4x8 beam. <br /> 11. Some posts in the cnwls� appear tc cansider lasds from above when plaama�t <br /> occurred, others do not. All point losds and wuform loads are tequired to be suppocud. <br /> Pcepare a response letter showing where each item in this cornection letter is addres�ed on flk plan <br /> set. <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommencx. <br /> All required submittals shall be of sufficient detail and contain sufficicnt information to ensure that <br /> the proposed suucture will be consuucted in compliancx with all adopted codes. <br /> Sincerely, <br /> �� <br /> eff Heilman <br /> D�vdopment Technician <br /> m:r+.a.+�.� <br />