My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1415 ROCKEFELLER AVE 2016-01-01 MF Import
>
Address Records
>
ROCKEFELLER AVE
>
1415
>
1415 ROCKEFELLER AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/27/2017 10:52:05 AM
Creation date
2/27/2017 10:51:48 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
1415
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. � � � <br /> � <br /> , � <br /> , <br /> May 12, 2014 <br /> Robin Jorgensen <br /> 1415 Rockefeller <br /> Everett, WA 98201 <br /> Subject: Project: Jorgensen <br /> )ob Address: 1415 Rockefeller <br /> Plan Check No: 6140�4-037 <br /> Dear Mr. Jorgensen: <br /> In response to your application for a construdion permit, your plans have been examined and <br /> you are advised that the issuance of a permit is being withheld for the reasons listed below. <br /> These comments address building issues only. Additional revisions or additions may be <br /> required by other departmentr (such as Utilities, Planning or Fire). All references refer to the <br /> (2012 International Building Code,} (2012 International Residential Code,) as amended by the <br /> State of Washington and/or Washington State Energy Code 2012 Edition, and adopted by the <br /> City of Everett, unless stated otherwise. <br /> In order for the processing of your application to contirtue, it will be necessary to <br /> provide the Building Division with two new oomplete sets of drawings reflecting the <br /> corrections requested, along with a reduced set of plans no larger than 11"x 17". <br /> 1. The soffit detail on sheet A-1.1 shows insulation at the roof parellel to the top chord of <br /> the attic trusses. The Floor plan of the attic area shows that the space is unheated. The <br /> ceiling above heated space is required to be insulated to minimum R-49. Show how <br /> ceiling above the main floor is insulated to min. R 49 (see "W"A5.0). <br /> 2. Provide 1-Hour fire —resistive construction on north exterior wall. Provide detail of listed <br /> 1-Hour assembiy with exposure from both sides. <br /> Please prepare a response letter showing where each item in this correction letter is <br /> addressed on the plan set. <br /> C\Iknral<I�nn�Drcumnnh\A III MRN PFRMR RFSDpNSF\Carml Rocmn<n M RM lnrnonwn rinr //� <br />
The URL can be used to link to this page
Your browser does not support the video tag.