My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1801 ROCKEFELLER AVE 2016-01-01 MF Import
>
Address Records
>
ROCKEFELLER AVE
>
1801
>
1801 ROCKEFELLER AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/27/2017 11:37:38 AM
Creation date
2/27/2017 11:37:28 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
1801
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PUBL/C N/OR/C5 <br /> February 11, 2011 <br /> Dave Pedersen <br /> P.O. Box 12094 <br /> Everelt WA 982�6 <br /> Subject: Pioject: Soiheim <br /> Job Address: 1801 Rockefeiler Ave <br /> Plan Check No: B1101-025 <br /> Dear Mr. Pederson: <br /> In response to your application for a construction permit, your plans have been examined and <br /> you are advised that the issuance of a permit is being withheld for the reasons listed below. <br /> These comments address building issues only. Additional revisions or additions may be <br /> required by other departments (such as Utilities, Planning or Fire). All references refer to the <br /> (20C4 International Building Code,) (2009 International Residential Code,) as amended by the <br /> State of Washington and/or Washington State Energy Code 2009 Edition, and adopted by the <br /> City of Everett, unless stated otherwise. <br /> In order for the processing of your application to continue, it will be necessary to <br /> proNide the Building Division with two new complete sets of drawings reflecting the <br /> corrections requested. <br /> 1. Specify plate height on sedion and elevation <br /> 2. Specify roofing material and moisture barrier on roof <br /> 3. Specify siding material at north and south elevations, including gables <br /> q, Overhangs are shown as 12", 16"and 28". Please clarify <br /> S. Projections into the 5'side yard setback are required to be protected with one- <br /> hour fire-resistive construction on the underside <br /> 6. The APA portal frame included with the submiltal is only allowed in seismic <br /> design category (SDC) A, B and C. We are in SDC"D", provide portal frame <br /> detail with holddowns <br /> Please prepare a response letter showing where each item in this correction letter is <br /> addressed on the plan set. <br /> Sl.vliiv�n�¢Jnunulloi.o2<llenl RrcAd<Iln Mc) <br /> CITY OF EVERETT • 3200 Cedar Slreet • Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8882 Y <br /> Z <br />
The URL can be used to link to this page
Your browser does not support the video tag.