Laserfiche WebLink
'94 <br />EVERETT NVATER COMPANI. <br />Vol....( <br />CIRCULAR <br />Page-•-- <br />PLUMBERS AND PIPE FITTERS <br />In ndtlit.ion to the rules and regulationsrof the Gnnpaur re. <br />specting wafer supph', the followiii, instructions are published <br />for the information and guidautce of plumbers, pipe -litters and :ill <br />per,nnsconcerned: <br />On the btlek of this sheet a statement of the work done :ntd <br />lixtures put in must be made by tile plumber mid returned to the <br />otlicc of the Cuntpauty. <br />Ill all cases a "stop and waste" must he put in, and so placed <br />that it is easilV nccessihle to the consumer, and in such a position <br />that it will tlraiti all the pipes. If placed outside the building it <br />must he boxed, so that it caul he rtsily reached, and so that it <br />caul he protected Irom frost. :kII pipes, inside:ntd outside, must <br />Ile laid free from traps so that then will drain when the waste is <br />opcu. <br />files in the ground must be laid not less than twent v-four <br />inches below the surface. <br />All pipes most be run so Its to avoid stoppages and all traps <br />must be well secured. <br />\n bushing must be used to connect with the stop -cock nt the <br />sidewalk; nipples or reducing sockets mac he used if necessary. <br />No pipe can rut between the Coll' Pan f's service -cock and <br />utain, and it, case a water meter is set, no pipe must be connected <br />outside the meter. <br />19unthers ntaty turn on water fn: the purpose of testing their <br />pipes, but tiler must ICVe it shot off at the Contpanr's service_ <br />cock, and in no case turn on the water for consumers'. <br />The water will not be turned on to :un• premises until the <br />statenlent herein required has been furnished to the Company <br />all(] the inspector shall certify that tilt wort: has been done in <br />accordance with its rules and regulations. <br />A. C. PATTERSON, <br />Superintendent Everett water Compnny. <br />