My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 COLBY AVE COURTYARD BY MARRIOTT 2017-07-05
>
Address Records
>
COLBY AVE
>
3003
>
COURTYARD BY MARRIOTT
>
3003 COLBY AVE COURTYARD BY MARRIOTT 2017-07-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/5/2017 1:32:33 PM
Creation date
2/27/2017 2:06:12 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3003
Tenant Name
COURTYARD BY MARRIOTT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
652
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mezzanines shall be marked with the letter"M". When there is more than one mezzanine, <br /> they shall be marked with the letter "M" followed by numbers, in ascending order. Example - <br /> "Ml", "M2", etc. <br /> Parking garages shall use the letter"P"to designate floors. <br /> When there is more than one parking level below grade, they shall be marked with the letter <br /> "P" followed by numbers, in descending order. Example - "P01", "P02' , etc. <br /> Large parking structures may use letters to designate columns for ease of locating <br /> automobiles. Example - "Floor P3, Column E". <br /> 34. A room numbering footprint shall be provided to the Fire Marshal's Office for approval of <br /> floor/building numbering. <br /> 35. All fire alarm control panels (FACP) and sprinkler valves shall be in heated rooms or closets <br /> with standard man door access. Locations shall be approved by the Fire Code Official. <br /> 36. The location of Fire Department connections (FDC) and post indicator valves (PIV) shall be <br /> determined by the Fire Code Official. If immediate outside mandoor access is available to <br /> the sprinkler valves (risers), a PIV will not be required. <br /> Place the FDC at the NW corner of the building. <br /> 37. Dumpsters over 1.5 cubic yards capacity shall be located a minimum of 5 feet from the <br /> building [IFC 304.3.3 and 304.3.4, 2009 Edition]. <br /> 38. Buildings or portions of buildings or facilities exceeding 30 feet in height above the lowest <br /> level of fire department vehicle access shall be provided with approved fire apparatus <br /> access roads capable of accommodating fire department aerial apparatus. Overhead utility <br /> and power lines shall not be located within the aerial fire apparatus access roadway. <br /> 39. Fire apparatus roads shall have a minimum unobstructed width of 26 feet in the immediate <br /> vicinity of any building or portion of building more than 30 feet in height. At least one of the <br /> required access routes shall be located within a minimum of 15 feet and a maximum of 30 <br /> feet from the building and shall be positioned parallel to one entire side of the building. <br /> 40. Where elevators are provided in buildings, at least one elevator shall be provided for fire <br /> department emergency access to all floors. The elevator car shall be of such a size and <br /> arrangement to accommodate a 24-inch by 84-inch ambulance stretcher in the horizontal, <br /> open position and shall be identified by the international symbol for emergency medical <br /> services (star of life). The symbol shall not be less than 3 inches high and shall be placed <br /> inside on both sides of the hoistway door frame. <br /> Exception: If all stories within the building have direct, accessible egress to grade (EMC <br /> 16.01, Section V). <br /> 41. Provide to the Fire Marshal's Office a building footprint and lot layout on a CD or DVD. <br /> 11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.