Laserfiche WebLink
PUBLIC WORKS PERMIT COMMENTS <br />4. Connect side sewer per City Standard #G01. <br />5. Connect side sewer per Cily Standard #'s 601, 602, G04. <br />6. Conne�t all rooftop downspouls lo lhe side sewer. <br />7. Connect rooflop downspouts to lhe drainage system provided for this lot. <br />8. Rooftop runo(f must be discharged to a roof downspo�l infiltration system per City of Eve�eR Storm <br />Manual 3-2.6.2. The approximale size trench is 3.5' wide, 2' deep and 25' long. See attachment (or <br />more details. <br />l� � The coNractor must meet with lhe Public Works Inspector lo discuss polenlial drainage routing prior to <br />beginning the project. <br />/ 10. Install erosion conlrol measures as determined hy the Public Works inspector, such as silt (ence, straw <br />�� bales, swales, or erosion blankels. <br />1 t. Inslall erosion control measures per City of Everett Slandards for small parcels <br />b 12. Remove erosion conlrol measures upon completion of the project prior lo final approval of the permil. <br />13. All excavaled material from foundation, side�valk and driveways shall be hauled to an approved, <br />1 permilted site. No wasting of malerial is allowed on lhis building lol. <br />16. <br />No dirt, nwd, rocks or debris lo be tracked onto roadtivay. <br />No building materials lo be slacked on sidewalks and sidewalks lo be hept clean and open for <br />pedesUian travel. <br />Adjust water meter box 1" above sidewalk grade. <br />17. Remove and replace curb, gutter and sidewalk as per City o( Everett Slandard Plan #'s 305A & 306 on <br />lhis proposal's fronlac�e as directed by the Public Works Inspeclor (i.e. all unused driveways and any <br />broken or damaged area must be replaced). <br />� <br />19. <br />Inslall a Type I concrele driveway per Cily of Everett Slandard #307. <br />Pave driveway from the fronl property line out lo the streel paving. <br />20. Contact the _ <br />se�ti•er servic�s. <br />21. <br />22. <br />23. <br />Water District for connecling provisions for this building's waler and <br />A calch bas'n as per City Standard Plan #40't with a gas trap per Standard Plan #410 is required (or lhe <br />parking area. <br />If a sewer pump system is to be installed, the pressure line must diccharge inlo a private manhole, then <br />gravity ilow across the public ri�ht-of-way. <br />A sprinkler syslem is required (or Ihis 6uilding in compliance �vith the renuiremenls of NFDA Standards <br />?3D. <br />F�;; commenis <br />�2 <br />