Laserfiche WebLink
Ltr. Fagerlie (CO510-006) <br />May 16, 2007 <br />Page 2 <br />8. Dimension all interior partitions. <br />9. Provide minimum 36" clear width at stairs. Show handiail on plans. <br />10. Designate safety glass in hazardous locations per R308 IRC show on plans. <br />11. Provide details and/or sections for balcony framing and guard conswction. <br />12. Specify all window sizes and U-value. <br />13. Provide gravity calculations for 3'h foot cantilever. <br />14. 'The plans call for a"U210-2" hanger for a 6 x 12 beam. The Simpson Catalog calls <br />out a "HU612." Please clarify. <br />15. Because the footprint has changed a review by the Planning Department for <br />compliance with zoning code is required. Provide a detailed site plan with all <br />revisions. <br />16. Provide footing for point load from beam "M03" on main tloor framing plan. <br />Please prepare a response letter showing where each item in diis correction letter is addressed <br />on the plan set. <br />Upon resubmittal of the drawings, your application will bc given priority and plan review will <br />recommence. <br />All required submittals shall be of sufficient detail and contain sufficient information to ensure <br />fl�at the proposed structure will he constructed in compliance with all adopted codes. <br />Sincerely, . � <br />� y1 <br />� /�� /'./,l,�V <br />/ <br />Jeff Heilman <br />Development Technician <br />UIiUI�PI.NCAMSiP1111JL�UN:C1I510006 (J111 ROCKfI'[LLIiR A\'li) � <br />