My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3723 ROCKEFELLER AVE 2016-01-01 MF Import
>
Address Records
>
ROCKEFELLER AVE
>
3723
>
3723 ROCKEFELLER AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/4/2017 10:31:51 PM
Creation date
2/27/2017 2:21:39 PM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3723
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Standard 24 f'or private fire mains. (I3elo��•-aroun�l uit�in� must be installed bv �i'ashin¢ton <br />State 1'atrol Liceused UnderQround Sprinkler line certi�ed °Lf" installers. Fm• further <br />infm•mation, contact the Stntc Tirc Mar:�l�al's Office at (3G0) 570-3134 or contact the <br />F��erett rire Uepartment at (d25) 257-81':s3.) AII such tests shall be ���itnessed by a Pire <br />Department inspector. Call (d25) 257-�1124 to make an appointment for inspection. <br />Conu•actors' materials and test certificatcs shall be submitted to the Everett Pire Department <br />prior to issuance of any e�����r��«s oro«unancy. Call (425) 257-8123 for more informntion. <br />C. Tlirce Units or Lar�er - Size of fire sprinklcr ser��ice anJ mcter shall be calculated by a civil <br />cngincer or tire sprinkler designer who is solely responsiblc for this calculation. Thc Citp <br />Public Works DeparUnent does not re��ie�v these calculations and is not the authority having <br />jurisdiction. All buildings 3 units or larger that arc reyuired to have a fire sprinkler must have <br />a separate tire service. Pire services larger than 2" must conform to Ciry ot Everett I'ublic <br />\Vorks Stan�ard 515 and 523. The fire scrvice side of the system must ha� e a state-approved <br />hackllo��� prevention dcvice. <br />7. Por fir� safcty in multi-tamily projccts with community laundry facilities, thc following is <br />required: <br />a. �\ seI(-clusing, solid core door shall Ue installed (or the I;iundrl' roont. Any restraining <br />device shall hc aclivatcd b� an a�pro��ed smokc detcctor. <br />h. A covered metal coni:iiner shall be provided for U�c disposal of combustible �vaste in the <br />laundry room. <br />8. Pcrmits arc rcyuircd t7om thc �irc Urpartmcnt for rcmoval and iustallation of undergruund <br />fucl tunks. <br />9. Abandoned tanks shall be pumped uut and tBe fuel properly disposeJ of prior to removal. No <br />product or rinsc ���ater mtq� bc disposcd of in such a���ciy th;tt it could cntcr thc storm drains <br />syslem. <br />10. All fire alann control panels (PACP) an� sprinklcr valves shall be in heated ruotns or closets <br />with standard man door acccss. Locations shall hc :�nn��,���a ny thr Fire �f:ushal's Officc. <br />1 l. 'I'rash Collcc(ion - Dump:;tcrs o��cr 1.5 cubic yards r.;;+acitl' shall hc locatcd a minimum of 5 <br />fect from thc building �IPC 30�l.3.3, 20U3 [dition�. <br />12. A Vublic �Vorks Permit is reyuired Ibr this project. Detailed drawings in accordance <br />���ith Ciii� Design and Construrtiun Standards shall bc submitted to Ihe Public �Vorks <br />Depaitment, showing site parkine la1'out, landscapine, utilities, storm drainage, <br />temporary cunstruction crosion control, and all requircd itnprovements in the public <br />i ight-of-way. Public \�Vorks Department appro��al of these draa�ings is required prior to <br />any rcrmits hcing issucd. All impro��ements sh:ill be complered and approved <br />��arr.mtcd hcfore thc Occupancy Permit is issued/tinal approval is granted. <br />13. Parkine nwst he ��cr Cit�� 7uning Codc and Cil�� Dcsign and Construclion Standards for <br />Dcv�lopmcnt <br />d <br />
The URL can be used to link to this page
Your browser does not support the video tag.