Laserfiche WebLink
CASCADE TESTING LABORATORV. INC. <br />1'ESTING 0 INSPECTION / ENGINEERS /GEOLOti15T5 <br />June 14, 1984 <br />Cert. No. 845-61G <br />Kenr��ore Pre-Mix <br />Page 4 <br />We recommend that a representative of the soils engineer ebserve <br />the driving of all piling. The piling should be driven to five (5) <br />tons more than the requi�ed tonnage as measured by the E.N.R. <br />formula (i.e, thirty (30) tons E.N.R. for twenty-five ("l5) tons <br />workiny load). <br />Yarking and Drive Areas <br />We understand that paving is not planned in the parking and drive <br />areas. Placing crushed rock in the driveway and parking area will <br />gre�tly improve their year raund trafficability. Grading the sur- <br />faces so that water does not pond is also advisable. <br />