Laserfiche WebLink
8-inch address numbers shall be utilized. <br /> 5. Garages (in new metal shop area) -Install a portable fire extinguisher with a minimum U.L. <br /> rating of 2-A:40-B:C within 30 feet travel distance of all portions of this building. See 2012 IFC, <br /> Table 906.3(2). <br /> 6. Hazardous Materials- In order to expedite plan review, a hazardous materials inventory list <br /> shall be provided as a part of the submittal for building permit. The storage,handling and use of <br /> hazardous materials shall be in compliance with Chapter 50 of the IFC, 2012 Edition. <br /> 7. The storage,handling and use of flammable or combustible liquids shall comply with Chapter <br /> 57 of the IFC,2012 Edition. Quantities of solvents and flammables shall be figured when owner <br /> submits lists of products. Operations permit will be issued at time of inspection of business. <br /> Public Works Comments — Paul McKee—425.257.8810 <br /> A review of this project by the Engineering/Public Services Department indicates that the <br /> following conditions should apply: <br /> 1. A Public Works Permit is required for this project. Detailed drawings in accordance <br /> with City Design and Construction Standards shall be submitted to the Public Works <br /> Department, showing site parking layout, landscaping, utilities, storm drainage, <br /> temporary construction erosion control, and all required improvements in the public <br /> right-of-way. Public Works Department approval of these drawings is required prior <br /> to any permits being issued. All improvements shall be completed, approved and <br /> warranted before the Occupancy Permit is issued/final approval is granted. <br /> 2. Parking must be per City Zoning Code and City Design and Construction Standards <br /> for Development. All code required parking and any access driveways to these <br /> parking areas shall be paved. Any right-of-way along Rainier Drive not used for <br /> access driveways shall be landscaped to control vehicle access points. <br /> 3. Separate permit applications are required for each new or modified structure, with <br /> additional comments forthcoming from plan review. <br /> 4. Change of occupancy to single family residence should be shown to comply with <br /> International Residential and Property Maintenance Codes. <br /> 5. New roof at loading area should be shown to comply with International Building <br /> Code. <br /> 6. A common site plan indicating imaginary property lines between structures under <br /> permit and existing structures should be submitted with each permit application. <br /> 7. Any grading/fill on this site shall be done so as to not impact the surrounding <br /> properties. <br /> 8. If the project will result in 2,000 square feet or more of new plus replaced impervious <br /> surface, then stormwater shall be managed in accordance with the City's 2010 <br /> 10 Stormwater Management Manual. The manual can be found under "Quick Links" at: <br /> https://everettwa.gov/169/Permits <br /> REVII# 14-0j <br /> Page f <br />