My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5209 GLENWOOD AVE 2017-04-07
>
Address Records
>
GLENWOOD AVE
>
5209
>
5209 GLENWOOD AVE 2017-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2017 8:40:46 AM
Creation date
3/1/2017 3:56:09 PM
Metadata
Fields
Template:
Address Document
Street Name
GLENWOOD AVE
Street Number
5209
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
182
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> Revised Redi-Rock Retaining wall Design Western Geotechnical Consultants,Inc. <br /> 52XX Glenwood Ave.Property #14 91 2 <br /> Everett,WA <br /> April 17,2015 <br /> that results in the greatest dry density from compaction. We recommend using a relatively clean <br /> sand-gravel mix meeting the USCS gradation specifications for GW or SW soils or using ballast <br /> meeting the specifications contained in Sec 9-03.9(1)of the WSDOT"Standard Specifications of <br /> Road, Bridge and Municipal Constmction". Alternate backfill gradations may be used, subject to <br /> approval of the geotechnical engineer. <br /> Stability Analyses <br /> Stabilizing forces in the design result from the mass of the Redi-RockIMSE and friction between <br /> the Redi-Rock/MSE and the foundation soil. Stability analyses were performed using limited <br /> equilibrium techniques to analyze the margin of safety against sliding,overturning, internal <br /> buckling and global stability. The methods of analyses compute the ratio of forces (or moments) <br /> resisting movement, as compared to forces (or moments)tending to cause movement. <br /> We analyzed the wall designs for total wall heights tip to 24 feet high with an exposed height of <br /> 23 feet, assuming a minimum 1-foot embedment of the lowest block below finished grade, and <br /> the wall foundation pad must be constructed within the fresh, hard till. MSE wall sections,where <br /> geogrid is used to reinforce the soil,are required for all wall heights greater than 9 blocks high. <br /> The length of the geogrid reinforcement increases with the height of the wall. In general,the <br /> length of geogrid reinforcement is a minimum of 0.6 times the total height of the wall, except <br /> longer grids are required:near the top of the wall,as indicated on the design cross-sections in <br /> Appendix B. <br /> We analyzed the wall using both static and dynamic conditions. We determined that the static <br /> safety factors for sliding and overturning were in excess of 1.5 and 2,0, which represent the <br /> minimum safety factors normally used for static stability against sliding and overturning. <br /> respectively. Our dynamic analyses assumed a pseudostatic earthquake force equivalent to 20% <br /> of gravity. <br /> While the dynamic analysis revealed a minimum safety factor for most of the blocks of greater <br /> than 1.1, which is the norm by geotechnical engineering standards for dynamic analyses, there is <br /> a lower factor of safety for the upper block(s)during such a strong earthquake, which could <br /> result in some tilting of these blocks. This was compensated for by increasing the length of the <br /> top I to 2 geogrid layers. <br /> Bearing capacity for the wall was also analyzed and found to be adequate,assuming the removal <br /> of any unsuitable subgrade soil down to hard glacial till, which will require inspection and <br /> approved prior to the beginning of the wall construction. <br /> Construction Considerations <br /> 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.