Laserfiche WebLink
1 <br /> POWER SERVICE NOTE L i BATTERY COMPLIANCE NOTE -� Cti ,\ <br /> SEE PIONEER POWER SURVEY FOR CONFIRMATION THAT 9I PROPOSED FINAL BATTERY CONFIGURATION TO CONSIST OF(16) LEAD ACID BATTERIES. c�•, 4'�i~L i��`f I � \ /,•!� \ -, O <br /> EXISTING SERVICE IS SUFFICIENT AND ANY POWER �7"' , ---_ / P `' " <br /> UPGRADE REQUIREMENTS OR ADDITIONAL UTILITY SCOPE ' I �� - 2015 IFC COMPLIANCE' EACH BATTERY CONTAINS 2.34 GALLONS OF ELECTROLYTE FOR /1 L r _ \ . . . . vol.- 2.. <br /> BEYOND WHAT IS SHOWN ON THIS PLAN. ,ap \ A TOTAL VOLUME OF 34.44 GALLONS.AS THE TOTAL ELECTROLYTE VOLUME DOES NOT -- VV'p.t t`1i� i� .. <br /> Q ^=-- -->-------- EXCEED 50 GALLONS. COMPLIANCE WITH 2015 IFC SECTION 608 IS NOT REQUIRED. c� .(, `7\ ---- - ------- --- -- -- -- <br /> °D .1„........,,,,, 2018 IFC COMPLIANCE: EACH BATTERY IS RATED AT 2.28 KWH (12VX190AH/1000) FOR P " �` \` - �_ <br /> `j A TOTAL OF 36.48KWH.AS THIS DOES NOT EXCEED THE 70KWH THRESHOLD LISTED IN V V i 1 % <br /> n - 7 TABLE 1206.2 OF THE 2018 INTERNATIONAL FIRE CODE, COMPLIANCE WITH 2018 IFC \- r �7 _ <br /> L' G Q D•T-� SECTIONS 1206.2.1 THROUGH 1206.2.12.6 IS NOT REQUIRED. `J l\\--0 0<<� C - A <br /> V - - i ii`r <br /> �� o ?� l f �/I ��t > na �� <br /> 1 /✓ �, I \\ <br /> EXISTING' i� . `. ,� 9 ' 1 .%�, <br /> LANDSCAPING (TYP) i� I I ' G I <br /> EXISTING T-MOBILE 200A MAIN _ \y <br /> EXISTING TREE (TYP) V\ \ <br /> SERVICE DISCONNECT TO REIM _ O��I EXISTING T-MOBILE 200A MAIN A/C SERVICE DISCONNECT 7O REMAIN ,` � TM <br /> PROPOSED INTERECT 2ooA >Integrit DeliveredOELECTRICAL PANEL W/CAMLOCKEXISTING T-MOBILE METER TO RDNN ,/ EXIN �j (SE.E P'OWQt SN N � bYGENERATOR INTERFACE BOX (�POWER SVICE NOTE) / /�` LANDSCAPINGi jEXISTING T MOBILE METER TO RF]IAMI EXISTING T-MOBILE TELCO / / ✓ /, (SEE POWER SERVICE NOTE) / <br /> g RE L Ca m DEMARCATION BOX TO RE1WN / / /f ' i ��00/ <br /> W /® / EXISTING TREE(TYP) __1 lI'� /O��/ REDS VERSION 6 <br /> / / EXISTING T MOBILE TELCO1/ / ✓�/ <br /> / / DEMARCATION BOX TO REMAIN <br /> m EXISTING T-MOBILE / .\ <br /> oz ACCESS GATE PROPOSED T-MOBILE MV'CUBE• / / ,�; I / \ i� // / <br /> a /SCORE. <br /> CABINET W/RELOCATED 4 // ACCS'EDSNSG�T-MOBILE i �'EC ROUTER (SEPARATE UTILITY 3 "RIGID CONDUIT FROM COOR / //.T CH LIGHT JUNCTION BOX % CASCADE HS/ <br /> ToPPc (1TorAL) p©� %,..., <br /> II I I i) o �- / /ii/// SNO-PUG/ <br /> y ,�'.116% GRACE <br /> / / / i / <br /> iLl r - / / EXISTING T-MOBILE A/C -y"`%� <br /> EXISTING Ilse ]-1 EXISTING <br /> p GRAVEL •k o v q /// GRAVEL PLUGPLU TWA GENERATOR <br /> Q,/ ' <br /> 2 AREA WITHIN `�- / / AREA WITHIN I I AA,/T S Eel 1610C <br /> COMPOUND I x i / COMPOUNDEXISTING 0 7 m/w / 7 CABINET TO BE IREl/OVED / //�/ <br /> { I -.At <br /> ,I i / 4//I <br /> / EXISTING T-MOBILE LEC ROUTER / / / <br /> illcT ����" / WITHIN POWER/BATTERY CABINET / / / <br /> g , I A 1 / TO BE RELOCATED TO PROPOSED �/ 8401 HOLLY DR <br /> 'CUBE'TELCO CABINET 4)'/ / <br /> / / // EVERETT,WA 98208 <br /> \ (SEPARATE UTILITY SCOPE, / <br /> 3 '\ / OORDNATE w/CM) / *// SNOHOI�IISH COUNTY <br /> T- PROPOSED T-MOBILE /�j/� I I E%ISTING T-MOBILE 6'0 PVC <br /> 24•WIDE GRIP STRUTEXISTING T-MOBILE 6.0 PVC EXISTING T-MOBILE PURCELLCONDUITS ROUTED UNDERGROUND <br /> STEP-OVER COVERING / CONDUITS ROUTED UNDERGROUND72 POWER/BATTERY (4 TOTAL)TO REWW O4-Z7-ZO21V (4 TOTAL)TO ROANN CABINET 70 EE REYOVED40' <br /> PROPOSED TT-MOBILEPROPOSED T-MOBILECTOOAX�(R PEa�SECTOR, 8 TOTAL) \A CDLED TECH ucHr1ox1s qO RABX43 W/TMER doCONCRETE7FIGS 2.0 HYBPoD FlBFR EXISTING T-MOBILEo TRUNKS ROUTED INSIDE TECH LIGHT �/ <br /> liii <br /> } A <br /> DUPLEX RECEPT PAD EXISTING T-MOBILE HI CAP C_ F WAS <br /> w <br /> o EXISTING CONDUITS (2 TOTAL) 70 BE REPLACED - HCS HYBRID FIBER TRUCK �� .ty/,yc <br /> m I I • _ (1 TOTAL)TO BE REMOVED <br /> Si I - EXISTING T-MOBILE 6\ . <br /> "0 J tie v4 , <br /> o 4- I CONDUIT STUB-UPS (4 TOTAL) _ , "� Z <br /> ( - u -EXISTING T-MOBILE COUP UNIT <br /> p I ON UNISTRUT H-FRAME <br /> • I PROPOSED T-MOBILE HSC 2.0 // /v'�O'� — (1 TOTAL)TO BE REMOVED 1/,,��-� , -�` <br /> • I OW JUNCTION BOX MOUNTED ON , a L W �� II 1' . <br /> PROPOSED T-MOBILE (2) NEW ANIA - ICE EIRIDGE UNISTRUT(3 TOTAL) •-B T MOBILE <br /> z SUBRACKS WI BASEBAND MODULES •I po EXISTING T-MOBILE 6"m `;A ,WF •3� O <br /> PER REDS, (1) VOLTAGE BOOSTER, 1 ' I I CONCRETE - CONDUIT STUB-UPS (4 TOTAL) 0,l�\ G1 STE- <br /> W (1) NEW CSR IXRE, AND (1) r- — —I `? I I PROPOSED T-MOBILE CONDUITS PAD \ G\ <br /> rc RELOCATED FSMF (DOCUMENTED AS --_-----+-y 11 J �/ TO HPL3 CABINET(5 TOTAL): _ EXISTING T-MOBILE GPS S/ANAL EN <br /> VERSION 105 AND SUITABLE FOR W I -- --•- 1 _J (1) 2• RIGID FROM MV CUBE. ANTENNAS (3 TOTAL) <br /> z RE-USE, FIELD VERIFY AND NOTIFY ��,2_p"... n I (I) 2• RIGID FROM PPG. 9 (ACTIVE GPS TO BE RELOCATED, <br /> CM IF OTHERWISE) WTTHIN i A- 1 AND (1) 2• RIGID FROM - INACTIVE GPS TO BE REMOVED) <br /> PROPOSED HPL3 CABINET , KEEP CLEAR :Ill EACH OVP JUNCTION Box ` EXPIRES 01-09-2022 J <br /> _ I r_r___--,-- I I EXISTING T-MOBILE NOKIA <br /> ©Q PROPOSED T-MOBILE PURCEU_ �M• ULTRASITE CABINET(1 TOTAL) <br /> rc HPL3 600A DC POWER PLANT/SSG L _ __ PROPOSED T-MOBILE ICE BRIDGELI <br /> TO BE REMOVED REVISIONS <br /> O `✓r /� ILA i ��. REV. DATE DESCRIPTION BY <br /> 0. <br /> i `- IN EXISTING T-MOBILE NOKIA A 03/31RT ISSUED FOR 900 CO RENEW OF <br /> a 0 8i PROPOSED T-MOBILE HYBRID FIBER <br /> FCOA CABINET (1 TOTAL) 0 04/23/21 ISSUED FOR 100E CONSTRUCTION AF <br /> / 1Oa JUMPERS FROM HPL3 CABINET TO TO BE REMOVED <br /> OW JUNCTION BOXES (3 TOTAL) - ' <br /> w I EXISTING T-MOBILE (5) <br /> D I o\ RELOCATED EXISTING FSMF WITHIN FCOA CABINET <br /> p T-MOBILE GPS ANTENNA(S) (4)TO BE REMOVED, (1)TO <br /> o -.- BE RELOCATED TO PROPOSED <br /> z ,_ - HPL3 CABINET (DOCUMENTED <br /> 05 AND SUITABLE <br /> FORI AS�RE-USE,SION 1 FIELD VERIFY <br /> ttII /,� AND NOTIFY CM IF OTHERWISE) "- ' <br /> 1 .-- _- <br /> O ////// _ — <br /> — <br /> V <br /> 0 EXISTING T-MOBILE / ---- --f <br /> 6' HICEH WOODECOMPOUND <br /> I EXISTING T-MOBILE / �/I TITLE <br /> ti 'FENCE COMPOUND - / / '!/ <br /> m 6' HIGH WOODEN <br /> 0, _ FENCE COMPOUND ', EXISTING PROPOSED <br /> PROPOSED T-MOBILE PURCELL LB3 I �/ / <br /> , \-._ ) <br /> z ©�STRINGS CABINET <br /> (4) (16 CELLS TOTAL) OF 7/ ///r <br /> Tom,, w�T VALVE REGULATED LEAD ACID BATTERIES / SHEET <br /> (SEE BATTERY COMPLIANCE NOTE) <br /> LEXISTING L EXISTING <br /> AREA-7 _.. ..._ ------Z TREE �7LA <br /> �`� EVERETT_.. \�i�' <br /> z0 <br /> _�►_ REVIE E OR PERMITA-3 <br /> 11. `S / <br /> TRUE NORTH TRUE NORTH <br /> `21 %17" SCALE: 1/4" 1'-0• p' 1 0• I PROPOSED EQUIPMENT PLAN 2 24 N s•SCALE: <br /> 1/2 _ ,•-o• 2' �• I EXISTING EQUIPMENT PLAN I (GLOTELPROJECT#: J6561) <br /> "x <br /> 5120 <br />