33'-0" <br /> NOTES: ` <br /> 10'-3" 7'-9" 15'-0" <br /> THE EXISTING ELECTRICAL WALL HEATER / <br /> AND HOT WATER TANK TO BE REMAINED <br /> UNCHANGE. >- <br /> EXTRA FOOTAGE WILL BE HEATED BY <br /> ELECTRICAL WALL HEATER IF NEEDED AND \ 36•HT RAI .G 6X6 P.T.POST <br /> INSTALL AS MANUF. SPECS. 2R DN TYPICAL LTJ <br /> LIGHTING SECTION 505 (WSEC) Covered de k o <br /> 0 2X DECKING 7n CC <br /> INTERIOR A MINIMUM OF 50 PERCENT OF ALL - al <br /> � 3' 0" 3'-71° 3'-71 <br /> LIGHTING LUMINAIRES SHALL BE HIGH f 1050 FIX 1050 FIX 36'HT RAIUNG THIS IS OPTIONAL <br /> 505.1 (WSEC) EFFICACY LUMINAIRES <br /> LUMINAIRES PROVIDING OUTDOOR DN Jr <br /> EXTERIOR UGHTING AND PERMANENTLY MOUNTED -,UGHTING TO A RESIDENTIAL BUILDING OR TO a o Covered deck <br /> 505.2(WSEC) OTHER BUILDING ON THE SAME LOTi v 2X DECKING 3R DN <br /> SHALL BE HIGH EFFICACY LUMINAIRES E.r t ry <br /> SMOKE DETECTORS EXISTING EXISTING <br /> A SMOKE DETECTOR SHALL BE INSTALUID IN EACH HABITABLE R001.1. ARCH WAY <br /> A SMOKE DETECTOR SHALL BE CENTRALLY LOCATED ON EACH FLOOR. <br /> AN ADDITIONAL SMOKE DETECTOR SHALL BE INSTALLED IN EACH <br /> LOCATION WHERETHERE IS A CEILING HEIGHT CHANGE GREATER THAN <br /> 24'SMOKE DETECTORS TO BE 110v HARDWIRED,INTERCONNECTED, <br /> 1111H BATTERY BACKUP PER SRC R313 c.v <br /> CARBON MONOXIDE DETECTORS S °1SDW Kitchen <br /> SRC R 314.3 CARBON MONOXIDE ALARMS. <br /> FOR NEW CONSTRUCTION,AN APPROVED CARBON MONO70DE ALARM <br /> SHAM BE INSTALLED IN DEBELDNG UNITS AND IN SLEEPING UNITS <br /> WHIN WHICH FUEL-BURNING APPLIANCES ARE INSTALLED AND IN <br /> DNEWNG UNITS 114AT HAVE ATTACHED GARAGES. <br /> REF. <br /> Linving room f <br /> L___J <br /> COMPOSITION ROOFING ' <br /> 15/FELT PAPER EXISTING 5 STOPS DOYM <br /> 7/16' SHEATHING 111141LANDING <br /> ROOF FRAMING PER MFR. • <br /> INSULATION BAFFLE � Nook <br /> VENTED BLOCKING AT ALTERNATE BAYS ��� <br /> 5/4 x 8 FASCIA PL N ������ <br /> CONTINUOUS METAL GUTTER ii'ti ������ <br /> WINDOW HDR.PER PLAN ! EXISTING <br /> R-49 INSULATION ELECTRICAL METER <br /> 5/4 TRIM SURROUND �- <br /> ARCH WAY �� TO REMAIN <br /> ss.s.: <br /> WINDOW W/INS.GLASS <br /> 2x6 STUDS 0 16'O.0 �J <br /> R-21 INSULATIONI <br /> Dining <br /> 7/16'SHEATHING o <br /> SIDING PER ELEVATION 10 I �, bedroom 2 Utility <br /> TYVEK WRAP ,`nn y OCM <br /> • <br /> 3/4"T&G PLYWOOD GLUED&NAILED 13 ALARM <br /> FLOOR JOISTS PER PLAN •i 1 <br /> i� 60•x32' I 1 <br /> R-30 INSULATION - T/S EXISTING <br /> 5/4 X 10 TRIM BAND - ~�` 5119 FLS 01V <br /> l <br /> l i...• W 6068 BI-PASS - U <br /> 2X P.T. WOOD SILL - ��-C -z <br /> e REBAR PER DETAIL = -1.- o <br /> 4' CONT. TIGHIIJN I_„__11=II- '11, ',� <br /> � 11 11 13 <br /> TO STORM SEWER 4=11-11=1i' OY, EXISTING -n PLAN KEY <br /> "1=11II"..�,ia�,1,,f. `ry 6 NIL VAP.BARRIER --� WALLS. <br /> 4”-PERF.PLASTIC FTG.DRAIN = ! <br /> SET IN WASHED GRAVEL / EXISTING M NEW CONSTRUCTION <br /> W/FILTER FABRIC OVER bath <br /> EXISTING WALLS TO REMNN <br /> G • _ a.. _ EXISTING WALLS AND WINDOWS TO <br /> TYPICAL WALL SECTION N.T.S. <br /> pi 8 �- s� 3068 BE REMO W AND OR MOORED <br /> .. e .. ���� ���� NEW ODOR <br /> NOTE: 7/16" SHEATHING NOT REQUIRED ON EXT. WALLS WHERE T1-11 SIDING IS SPECIFIED <br /> (UNLESS NOTED OTHERWISE IN THE SHEAR WALL SPECIFICATIONS) EXISTING EXISTING <br /> r COSTING DOOR <br /> 6068 BI-PASS <br /> 110V 110V - <br /> OSD Om F-.--- <br /> \ EXISTING DOOR TO BE <br /> AREA SUMMARY EXISTING NEW o <br /> z _ REMOVED AND OR MODIFIED <br /> A, <br /> V) <br /> MAIN FLOOR: 1540 SF. 10 SF. S <br /> bedroom 1 M. bedroom <br /> TOTAL: 1540 SF. 10 SF. <br /> GRAND TOTAL: 1550 SF. - <br /> N OTES: <br /> REMODELING AS SHOWN ONLY-ANY OTHER <br /> MODIFICATION OR CHANGE IS NOT PART OF THIS <br /> DESIGN AND IS RESPONSIBILITY OF OTHERS riCONSTRUCTION NOTES: za'-," VERIFY / <br /> - CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS <br /> OF PROJECT AND REPORT ANY OMISSIONS OR <br /> DISCRPANCIESDESINER BEFORE TO CMENC <br /> WORK.DES GNERTOSHALLGNOT BE RESPONS BOLEMFOR TNG _JORTH <br /> DISCREPANT CONDITIONS RESULTING FROM UNAUTHORIZED <br /> WORK PERFORMED BY THE CONTRACTOR. <br /> - NO FIELD ALTERNATIONS WILL BE AUTHORIZED UNLESS <br /> ACCOMANIED BY REVISED DRAWINGS. <br /> PROPOSED MAIN FLOOR PLAN <br /> SCALE: 1/8" = 1'-0" <br /> T & L HOME DESIGN A3 DATE <br /> NGUYEN RESIDENCE 09-08-14 <br /> ADD: 1313 E. 61st ST. 10805 HOLLY Dr. INIT: <br /> T.N. <br /> TACOMA, WA 98404 PROPOSED PLAN EVERETT, WA 98204 6 PROJECT <br /> TEL: (253) 441-1651 PARCEL NUMBER: 537900002106 j E1 <br />