2012 Washington State Energy Code Compliance Forms for Commercial, Group R1,and>3 story R2 and R3 <br /> ![112miii, <br /> i 11 vim <br /> 2012 Washington State Energy Code Compliance Forms for Commercial,Group R1,and>3 story R2 and R3 Revised.lune 2013 <br /> Project Info Project Address 3901 Hoyt Ave. Date 10/16/2013 <br /> Everett, WA 98201 For Building Department Use <br /> Applicant Name: Architectural Werks, INC. F-) (3 C) <br /> Applicant Address: 19204 North Creek Parkway, Suite 110 Bothell, WA 98011 <br /> Applicant Phone: 425-823-2245 <br /> Project Description ❑ New Building ❑ Addition Alteration ❑Plans Included <br /> Lighting Compliance Path Lighting Power Density Calculations Q Total Building Performance <br /> (If Total Building Performance then only LGT-CHK is required.) <br /> Interior Lighting <br /> Building Area Method Space-by-space Method <br /> Compliance Option <br /> Interior Lighting System <br /> Description. <br /> Briefly describe lighting <br /> system type and features. <br /> Additions and Change of Space Use (C101.4.3 & C101.4.4) <br /> ❑ Addition area or Change of Space Use area complies with all applicable provisions as stand alone project <br /> ❑ Addition area or Change of Space Use area is combined with existing building lighting systems to demonstrate <br /> compliance with all applicable provisions <br /> Provide Building Area Method(LTG-INT-BLD)or Space-By-Space Method(LTG-iNT-SPACE)Compliance Form. Document maximum <br /> allowed and proposed(including existing if applicable)lighting wattage of Addition or Change of Use scope. Provide applicable lighting <br /> controls per C405.2 and commissioning of lighting controls per C405.13. <br /> Alterations, Renovations and Repairs (C101.4.3.1) <br /> ❑ 60%or more of luminaires in space replaced <br /> Provide Building Area Method(LTG-INT-BLD)or Space-By-Space Method(LTG-INT-SPACE)Compliance Form.Document maximum <br /> allowed and proposed(including existing)lighting wattage of project scope <br /> ❑ Less than 60%of luminaires in space replaced <br /> Provide Space-by-space Method(LTG-iNT-SPACE)Compliance Form. Document existing total wattage in space and proposed <br /> (including existing)lighting wattage of project scope <br /> [] Lamp and/or ballast replacement within existing luminaires only—existing total interior building wattage not increased <br /> ❑ New wiring installed to serve added fixtures and/or fixtures relocated to new circuit <br /> Provide applicable manual lighting controls(C405.2.1),occupancy sensors(C405.2.2.2),daylight zone controls(C405.2.2.3),specific <br /> application controls(C405.2.3),and commissioning of lighting controls per C405.13 <br /> ❑ New or moved lighting panel <br /> Provide all applicable lighting controls as noted for New Wiring,automatic time switch controls(C405.2.2.1),and commissioning of <br /> lighting controls per C405.13. <br /> ❑ Space is reconfigured-luminaires unchanged or moved only <br /> Provide all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. <br /> ❑ No changes are being made to the interior lighting and space use not changed. <br />