My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4508 EVERGREEN WAY 2016-01-01 MF Import
>
Address Records
>
EVERGREEN WAY
>
4508
>
4508 EVERGREEN WAY 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2017 1:26:19 PM
Creation date
3/3/2017 1:26:16 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
4508
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
■ <br /> • <br /> • <br /> August 11, 2004 <br /> Mr. Jacobson <br /> Prime Construction <br /> 5309 Glenwood Avenue#B <br /> Everett,WA 98208 <br /> Subject: Project: Jacobson <br /> Job Address: 4508-09g.. v g 2 C:Q wn.'( <br /> Plan Check No: B0408-008 <br /> Dear Mr. Jacobson: <br /> In response to your application for a construction permit, your plans have been examined <br /> and you are advised that the issuance of a permit is being withheld for the reasons listed <br /> below. These comments address building issues only. Additional revisions or additions <br /> may be required by other departments (such as Utilities, Planning or Fire). All references <br /> refer to the 2003 International Residential Code, as amended by the State of Washington <br /> and/or Washington State Energy Code 2003 Edition, unless stated otherwise. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Building Division with two complete new sets of drawings reflecting the <br /> corrections requested. <br /> 1. Provide gravity calculations for garage door headers. Double 2 x 6 appears to be <br /> inadequate. <br /> 2. Alternate braced wall panels are required to be minimum 2'-8" wide. 24" lateral <br /> restraint panel is not approved under the International Residential Code without <br /> engineering. <br /> 3. 1/2" x 10" anchor bolts @ 72" o.c., 7" minimum embedment. Minimum 2 each <br /> piece and within 12" of each end of each piece. 3" x 3" x 1/a" plate washer on all <br /> anchor bolts in braced wall lines. Section R602.11.1. <br /> 4. The maximum spacing of braced wall lines is 35', per Section R602.10.1.1. <br /> 5. All braced wall panels shall be clearly marked on the plans. <br /> Please prepare a response letter showing where each item in this correction letter is <br /> addressed on the plan set. <br /> DE DImLNCK SIR/II cL%IAN/B0403-oo3(4503 F.YERGREEN WAY) <br />
The URL can be used to link to this page
Your browser does not support the video tag.