I° <br /> Simple Heating System Size: Was iston State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling <br /> loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Therres ADU John Tregidga/JT Design <br /> 3509 Oakes Ave 14241 NE Woodinville-Duvall Rd.#224 <br /> Everett,WA.,98201 Woodinville,WA.,98072 <br /> Heating System Type: ®All Other Systems OHeat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> Design Temperature Difference(AT) 47 <br /> [Everett JC <br /> AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Conditioned Floor Area(sq ft) 710 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8.0 5,680 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions <br /> 0.30 115 34.35 <br /> Skylights U-Factor X Area = UA <br /> Instructions 0.50 4 2.00 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> InstructionsR_49 I 0.026 710 18.46 <br /> Single Rafter or Joist Vaulted Ceilings 1 U-Factor X Area UA <br /> Instructions Select R-Value I No selection <br /> Above Grade Walls(see Figure 1) J U-Factor X Area UA <br /> Instructions I 0.056 961 53.82 <br /> R-21 Intermediate v J <br /> Floors U-Factor X Area UA <br /> Instructions j <br /> Select R-Value I J No selection — <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions - -_.._ -.-- ----- <br /> Select . No selection <br /> R value -- <br /> Slab Below Grade(see Figure 1) F-Factor X Length UA <br /> Instructions --_--- " <br /> Select conditioning V-1NO selection — <br /> Slab on Grade(see Figure 1) F-Factor X Len r th UA <br /> Instructions J 0.360 120 43.20 <br /> R-10 Fully Insulated �1 <br /> Location of Ducts <br /> Duct Leakage Coefficient <br /> Unconditioned Space 4r <br /> 1.10 <br /> Sum of UA 151.83 <br /> Envelope Heat Load 7,136 Btu/Hour <br /> Figure 1. Sum of UAXAT <br /> Air Leakage Heat Load 2,883 Btu/Hour <br /> VolumeX 0.6 X AT X.018 <br /> Above Grade M. Building Design Heat Load 10,019 Btu/Hour <br /> Air Leakage a Envelope Heat Loss <br /> Building and Duct Heat Load 11,021 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heal Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 15,429 Btu/Hour <br /> Building and Duct Heal Loss X 1.40 for Forced Air Furnace <br /> Building and Duct Heal Loss X 1.25 for Heal Pump <br /> (07/01/13) 7 J <br />
The URL can be used to link to this page
Your browser does not support the video tag.