Laserfiche WebLink
July 15, 2014 IIS \�IL.,... <br /> r <br /> LABS <br /> Brian Hunt INDUSTRIAL <br /> HYGIENE <br /> Alternative Environmental Technologies SERVICES <br /> 5129 Evergreen Way D9 Laboratory I Management I Training <br /> Everett, WA 98203 <br /> RE: Metals Analysis; NVL Batch# 1411730.00 <br /> Dear Mr. Hunt, <br /> Enclosed please find the test results for samples submitted to our laboratory for analysis. <br /> Preparation of these samples was conducted following protocol outlined in EPA Method <br /> SW 846-3051 unless stated otherwise. Analysis of these samples was performed using <br /> analytical instruments in accordance with U.S. EPA, NIOSH, OSHA, CPSC and other <br /> ASTM methods. <br /> For matrix materials submitted as paint, dust wipe, soil or TCLP samples, analysis for the <br /> presence of total metals is conducted using published U.S. EPA Methods. Paint and soil <br /> results are usually expressed in mg/Kg which is equivalent to parts per million (ppm). <br /> Lead (Pb) in paint is usually expressed in mg/Kg (ppm) , Percent (%) or mg/cm' by area. <br /> Dust wipe sample results are usually expressed in ug/wipe and ug/ft2. TCLP samples are <br /> reported in mg/L (ppm). For air filter samples, analyses are conducted using NIOSH and <br /> OSHA Methods. Results are expressed in ug/filter and ug/m'. Other matrix materials are <br /> analyzed accordingly using published methods or specified by client. The reported test <br /> results pertain only to items tested. Lead test results are not blank corrected. <br /> For recent regulation updates pertaining to current regulatory levels or permissible <br /> exposure levels, please call your local regulatory agencies for more details. <br /> This report is considered highly confidential and will not be released without your approval. <br /> Samples are archived for two weeks following analysis. Samples that are not retrieved by <br /> the client are discarded after two weeks. <br /> Thank you for using our laboratory services. if you need further assistance please feel free <br /> to call us at 206-547-0100 or 1-888-NVLLABS. <br /> Sincerely, <br /> -� <br /> s s <br /> Nick Ly, Technical Director <br /> Enclosure: • AIHA LAP,LLC <br /> ACCREDITED LABORATORY NVL Laboratories, Inc. <br /> 1.888.NVl.LABS — A gl4MANtetifa9, ,t,, <br /> �^'—.. atiecneasmt <br /> 1.,888.(685.5227) �� at 4708 Aurora Ave N,Seattle,WA 98103 <br /> ciestag <br /> www.nvllabs.com /`/"Ing'' —lAB y V+ERt p 206.547.0100 I f 206.634.1936 <br />