Laserfiche WebLink
. 1 <br /> B. Water Penetration: No water penetration when tested according to ASTM E 1646 at the <br /> following test-pressure difference: <br /> 1. Test-Pressure Difference: 2.86 lbf/sq. ft. (137 Pa). <br /> C. Hydrostatic-Head Resistance: No water penetration when tested according to <br /> ASTM E 2140. <br /> D. Wind-Uplift Resistance: Provide metal roof panel assemblies that comply with UL 580 <br /> for wind-uplift-resistance. <br /> E. Thermal Movements: Allow for thermal movements resulting from ambient and <br /> surface temperature changes. Base calculations on surface temperatures of materials <br /> due to both solar heat gain and nighttime-sky heat loss. <br /> 1. Temperature Change (Range): 120 deg F (67 deg C), ambient; 180 deg F (100 <br /> deg C),material surfaces. <br /> 1.5 SUBMITTALS <br /> A. Refer to Special Provisions,Part 1, Section 1-06.7 of the WSDOT Standard <br /> Specifications,the Project Special Provisions, and the requirements herein for the <br /> required method of preparation and transmittal of submittals. <br /> B. Product Data: For each type of product indicated. Include construction details, material <br /> descriptions, dimensions of individual components and profiles, and finishes for each <br /> type of roof panel and accessory. <br /> C. Samples for Verification: For each type of exposed fmish required,prepared on <br /> Samples of size,indicated below: <br /> 1. Metal Roof and Soffit Panels: 12 inches (300 mm)long by actual panel width. <br /> Include fasteners, clips, closures, and other metal roof panel accessories. <br /> 2. Trim and Closures: 12 inches (300 mm)long. Include fasteners and other <br /> exposed accessories. <br /> 3. Accessories: 12-inch-(300-mm-) long Samples for each type of accessory. <br /> D. Shop Drawings: Show fabrication and installation layouts of metal roof panels; details <br /> of edge conditions, side-seam and endlap joints,panel profiles,corners, anchorages, <br /> trim,flashings, closures, and accessories; and special details. Distinguish between <br /> factory-and field-assembled work. <br /> 1. Accessories: Include details of the following items, at a scale of not less than 1- <br /> 1/2 inches per 12 inches (1:10): <br /> a. Flashing and trim. <br /> SEWER LIFT STATION NO.24 REPLACEMENT PROJECT,UP 3313 <br /> Division 7 Thermal and Moisture Protection Page 07411-2 April 2012 <br />