My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1510 SE EVERETT MALL WAY 2018-01-01 MF Import
>
Address Records
>
SE EVERETT MALL WAY
>
1510
>
1510 SE EVERETT MALL WAY 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2019 2:00:40 PM
Creation date
3/7/2017 10:02:14 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1510
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
215
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,_ <br />Aboveground sprinkler piping shall be hydrostatically tested as estabiished in NFPA Standard <br />13. Urderground piping shall be hydrostatically tested and Flushed as established in NFPA <br />Standard 24 for private fire mains. Below-around piuing must be installed b,t <br />WashinqYon SWte Patrol Licensed Underground Sorinkler line certified "U" <br />installers For further information contact the State Fire Marshal's Office at <br />j360) 570-3134 or contact the Everett Fire Department at (425) 257-8123. All <br />such tests shall be witnessed by a Fire Department inspector. Call (425) 257-8123 to make <br />an appointment for inspection. <br />Contractors' materials and test certificates shall be submitted to the Everelt Fire Department <br />prior to issuance of any Certificates of Occupancy. <br />Call (425) 257-8123 for more information. <br />13. A permit is required from the Fire Department to use any buiiding or portion thereof as a <br />high-piled storage area exceeding 500 square feet. Plans shall be submitted with <br />applications for such permits. <br />14. fire Safetv - Fire safety prectices during construction shall be in compliance with the <br />International Fire Code. <br />15. All fire alarm controi panels (FACP) and sprinkler valves shall be in heated rooms or closets <br />with standard man door access. Locations shall be approved by the Fire Marshal's Office. <br />16. Trash Collection - Dumpsters over 1.5 cubic yards capacity shall be located a minimum of 5 <br />feet from the building [IFC 304.3.3, 2003 Edition]. <br />BEST BUY BUILDING/PROPOSED REfAIL BUILDING <br />Access - O.K. as shown on the site plan reviewed. <br />2. When access to or within a structure or an area is unduly difficult because of secured <br />openings or where immediate access is necessary for life saving or fire-fighting purposes, the <br />Fire Department requires a key box to be installed in an accessible location. A rapid entry <br />system may also be desirable in order to avoid unnecessary damage while making entry to <br />any building during an emergency situation. <br />Please call (425) 257-8123 for further information. <br />3. Fire lanes shall be provided as required in Everett Municipal Code 46.44. 1=ire lanes shall be <br />identified by red curbs with white stenciling stating "NO PARKING - FIRE L4NE" and vertical <br />signs stating "NO PARKING - FIRE LANE - TOW AWAY ZONE." Location shall be approved by <br />the Fire Marshal. <br />4. PREMISE IDENTIFICATION AND ALL REQUIRED FIRE DEPARTMENT ACCESS <br />ROADS AND FIRE HYDRANTS SHALL BE IN SERVTCE PRIOR TO COM�IENCEMENT <br />OF CONSTRUCTION. <br />
The URL can be used to link to this page
Your browser does not support the video tag.