<br /> r
<br /> �
<br /> � �� �
<br /> C.' � H . � " � . . ,:
<br /> ��y �t�r�v Att�clment C ' �
<br /> �r
<br /> htlN� �' -
<br /> � �� Plans Examiner and Inspector Checklist
<br /> o� PertnitNo. 31 ��7 Address CoLUMg1A p�/E
<br /> ��g
<br /> �" � Plens Exeminer: Check,write in NIA, or fill in value on shaded boxes.
<br /> �y� Inspector: Check ofl boxes at leri as items are found to comply.
<br /> �.y y N Compllence approech:(check one) �Systems analysis L�J Component pertortnance ❑Prescriptive path
<br /> a �.t.:�
<br /> ��d y Note:Some specifics on lhfs fortn may not apply if
<br /> � � A) complfance approach is syslems analysis or component periormance;
<br /> Ho y B) compliance to minimum vantilation criteria is demonstrated through engineering calculations or pe�fortnance testing. '
<br /> FOIR�ATION PHASE
<br /> _.._.._
<br /> ❑ I b: �!�'.:,.j E�erlor down to irostllne/sleb bottom;or Interlor 24"hodzontel or vertical;or,B redlant,under entlre sleb '
<br /> ❑ rad��M�rlorwailln�uletlon: �_�'___� (Iflntedor—seelnsulaUonPhase) �
<br /> n itlgetlon:�It locally requlred,or crawlspace venNng<1fV300ft2 ot crawl,or vents Include en operaWe damper , �
<br /> FRAMRIG P11ASE � �
<br /> ,�
<br /> ,
<br /> L,��S,/Freming: �1�Standard nlntermedlete I_� Advanced �i ��
<br /> L�],�Std elr aeel:solepi/sublir,rim JsVmud s�ll;window 8 door Irms;penetratlon-wlre,ptumb,duct,partlUon studs,ilue,Ilght Iixtures � �!
<br /> LrJ" 5�urc�ep�cltlo exhaust t�ns: Slze requlrement—bath,laundry(SOcim);kllchen(t00c1m) ,' -%
<br /> ,..,,/ i�
<br /> '�1 L7 Whol�houn��xhewt ten �g� ot.m intermlttent system has manual 8 auto controls;Outdoor elr supply req.for heblteble rms. �,� .;.
<br /> Ior
<br /> 1 ' �Ilhwgreted torced-alr ay�t�m n outside air duct(with damper)allowing betwaen.35 end.5 ACH -;�
<br /> /IQ
<br /> � INSULATION i�lU1SE
<br /> —
<br /> ' 1 [����}j����j`] Wa0lnsuletlon(e6ow gred�) � -
<br /> '�' {-3' �u_,.__,.8.� Vlell In�uletlon(bslovi grcde):Interlor well insulatlon J
<br /> f�1 ❑ �{ �O_�,�,�.,_� floorinauletlon 1ti -��f���,
<br /> ' ' ���p �D__. I Celling Insulelion:Including attic hatch �
<br /> � -Q q._ ,� _� Vault�d ceiling Inaulatlon . ���'"�'
<br /> '� �Ve or roterdero:walls,Iloors celling �.
<br /> �' ,.,, � _. _..._ — —
<br /> LN'Heatlog system type: L ���C..C��_ . YI For heetpumps,Ilst slze,HSPF,end COP � :_ �
<br /> �
<br /> '�1 klnl� la'r IZ.S FINAI.PHASE '� �„
<br /> ' ' L7 Redon monitor on alte:wlth Instrucllons and general Inlormatlon �
<br /> �
<br /> �Thermostet:heal range,55-75;AC rnnge,70-85;both,55-85.Backup hea�conirols prevent slmultaneous opernUon of prlmary sys.
<br /> �� �-,,/ �
<br /> Li Solid fuel appllenees:glass or metal doors;dirad comb.alr source,or 4"dia.,dampered,Indirect source lor uncond.ereas �
<br /> , Q�Flreplaces:6"combustlon eir supply duct w/damper direcl to Ilrebox;tlght Otling gless or metal doors.
<br /> -. �DHW heatm:NAECA label;separate power or gas shut-oH;on R•10 pad if electdc and In umm�d.area or II on corrrote i4
<br /> ;
<br /> �Mechanlcel venllletlon ducts Ineuleted to R-0:exhaust duds in unconditloned areaslsupply duds In condltloneJ erees �
<br /> - ---
<br /> •� �- � � HVAC ductafplenum Insulallon:ducts In unwnditloned ereas ere Insulated and�olnts are seeled
<br /> �t'_.. .__...._--
<br /> 0' P�ps Insulatlon: R31or hot nnd cold waler p�ping In uncondltloned areas(If servlce or radreuleting,see Tabie S72) �
<br /> � Oround cover:6 mil bleck polyethylene.�approvad equal lepped 72"nt�olnts end extending to foundallon wall
<br /> y
<br /> �