Laserfiche WebLink
' �. � � <br /> 9. Show required attic ventilation on plans. Provide 1 sq. ft. cet clear ventilation for <br /> each 150 sq. ft. of attic area. May be reduced to 1 sq. ft. vendlation for each 300 <br /> sq. fr. If �k of required ventilation is at least 3 feet above soffit or eave vents and <br /> the remainder is in soffit or eaves. <br /> 10. Provide solid blocking over support in crawl space. <br /> 12.Elevation views are not complete. :'how all windows and doors in addition on <br /> elevation views. <br /> 12.Provide min. 36" landing no[ more than 8" below the finished tloor at all <br /> enuance/exits. <br /> 13.WA. St. Energy Code �WSEC) requires min. R-30 insulation in structures using <br /> electric resistance heat. <br /> 14.Habitable rooms other than a kitchen shall not be less �han 7' in any dimension. <br /> 15.Show roof framing including still framing over existing house. <br /> 16. Note on drawings: <br /> • Maintain less than 18" clear crawl space. <br /> • Maintain min. 12" clear under girder. <br /> • Nailing per table 23-11-B-1 UBC. <br /> • Assumed soil-bearing pressure 2000 PSF. <br /> • Double top plate, lap splices 48". <br /> Please provide a response letter showing where each item in this correction letter is <br /> addressed on the plan set. <br /> Upon resubmital of the drawings, your application will be given priority and plan <br /> review will commence. <br /> All required submittals shali be of sufficient detail and contain su�cient information <br /> to ensure that the proposed structure will be constracted in compliance with all <br /> adopted codes. <br /> Sincerel , <br /> ��l <br /> J Heilman <br /> Development Technician <br /> 1H:jCc0005-019 <br />