. �� � <br /> PY/BL/C N/OR/CS <br /> J�iy 2, i�� <br /> Arun Sharma <br /> 5822 - lst Dr W <br /> Everett WA 98203 <br /> RE: Owner: Shazma <br /> Job Address: 5822 - lst Dr W <br /> Plan Check N:55703 <br /> Dear Mr. Sharma: <br /> In response to your applicatiun for a construction permit, your plans have been examined <br /> and you are advised that the issuan.c of a permit is being withheld for the reasons lisred <br /> below. These comments address building issues only, additional revisions or additions <br /> may be required by other departments (such as Utilities, Planning or Fire). All <br /> references refer to the 1994 Uniform Buildi�,g Code, as amended by thc State of <br /> Washington and/or Washingtor. State Energy Code 1995 Edition, unless stated <br /> otherwise. <br /> In order for the processing of your application to continue, ic will be neccssary to <br /> provide the Building Division with two zomplete new sets of drawings reflecting the <br /> corrections reqaested. <br /> 1. 2 x 12 ridge boaid will not support roof rafters at ridge of addition. Provide size <br /> species and grade of ridge beam. <br /> 2. Show how roof rafters aze vented. Provide one sq. ft. net clear ventilation for each <br /> 150 sq. ft. of roof area. Show ventilation on plans. <br /> 3. Provide detail of balcony construction. Show I�ow balcony is drained. Detail <br /> guardrail construction. <br /> 4. Provide calculations fon c�ader at sliding glass door in family room. (supporting <br /> cantilevered deck). <br /> 5. Provide foundation plan. Show perimeter footing and all spread footings (at <br /> interior bearing walls). <br /> 6. Provide non-combustible heaith at fireplace. Hearth should extend min. 20" in <br /> front of and l2" beyend each end of fireplace opening, s��ow on plans. <br /> 7. All rooms and interior spaces shall be labeled. Verify light and ventilation <br /> requirements are met in area where bedroom was removed. <br /> 8. Trusses can not be modified without approval of a licensed Wa. St. St�uctural <br /> Engineer. The 3 1/8' x 12" glu-lam beam would have to be set under the existing <br /> trusses. The bottom of the beam cannot be less than 7'0" above the floor. <br /> CITY OF EVtRETT•3200 Cedar Street • Everett,WA 98201 • (425)257-8800• Fax (425)257-8856 <br />