Laserfiche WebLink
PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connect side sev+er per City Standard #601. <br /> �. � Connect side sewer per Cily Standard#'s 601, 602, 604. <br /> 6. Connect all rooftop downspouls to lhe siae sewer. <br /> / 7.� Connect rooftop do�vnspouts to the drainage system provided for this lot. <br /> L�� <br /> 8. Rooftop runoff must be discharged to a roof downspout infillration system per City of Everelt Storm <br /> Manual 3-2.6.2. The approximate size trench is 3.5' wide, 2'deep and 25' long. See attachment for <br /> more details. <br /> 9. The contractor must meel wilh lhe Public Works Inspeclor to diswss potential drainage routing prior lo <br /> beginning the project. Call Randv Allen at 4�5-339-7403 /1 Call Cliff Lindman at 425-339-7404. <br /> 10. Install erosion conlrol measures as determined by the Public Works inspector, such as silt fence, slra�v <br /> bales, swaies, or erosion blankets. <br /> 1 Install erosion control measures per City of Everett Standards for small parcels <br /> �—� <br /> �`�=Remove erosion control measures upon complelion of the project nrior to final approval of the permit. <br /> 13. All excavated material irom ndalion, sidewalk and driveways shall he hauled lo an approv�d, <br /> permitted site. No wasling o. niaterial is allowed on lhis buildinq lot. <br /> 14. No dirt, mud, rocks or debris lo be tracked onto roadway. <br /> 15. No building materials lc � . _.acked on sidewalk/roadway and sidewalk/roadway to be kept ctean and <br /> open for pedestrian tra� el. <br /> 1G. Adjus[v�aler meter box 1" above sidev✓alk grade. <br /> 17. Remove and replac�curb, gutter and side�v�;k as per City oF Everelt Standard Plan#'s 305A& 306 on <br /> this proposal's (rontage as direcled by the Public Works Inspector(i.e. all unused driveways and any <br /> broken or damaged area must be replaced). <br /> 18. Install a'Type I concrete driveway per Cily of Everett Standard #307. <br /> 19. Pave driveway from the front preperly line out to the street paving. <br /> 20. Pave to existing paving in alley. <br /> 21. Contactthe Water District for conrecting provisions for lhis building's water and <br /> sewer services. <br /> i 22. A calch basin as per Cily Slandard Plan it402 with a gas lrap per Standard Plan#410 is required for lhe <br /> parking area. <br /> 23. If a sewer pump system is to be installed, the pressure line must discharge into a private manhole, then <br /> gravity flo�v across the public right-of-�vay. <br /> 7_4. A sprinkier system is required (or lhis building in compliance with lhe requirements of NFPA SlandGrds <br /> 13 D. <br /> r;�c�R,�,�-�,i�i R���,_�a��e;t i <br />