, PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connect side sewer per City Standard#601. <br /> � Connect side sewer per City Slandard #'s 601, 602, 604. <br /> 6. Connect all rooftop downspouts to the side sewer. <br /> �� <br /> (� 7 Connect rooflop downspouts to the drainage system provided for this lot. <br /> 8. Rooftop runoff must be discharged lo a roof downspout infiltration syslem per City of Everett Storm <br /> �lanual 3-2.62. The approximale size trench is 3.5'wide, 2'deep and 25' long. See attach�nenl for <br /> more details. <br /> 9 The contractor must meet with the Public Works Inspeclor to discuss polenlial drainage routing prior lo <br /> beginnin3 lhe project. <br /> 10. Inslall erosion control measures as determined by lhe Public Works inspeclor, such as silt fence, slraw <br /> bales, swales, or erosion blankets. <br /> ,�r--. <br /> �i; 11. Inslall erosion conUol measures per City of Everelt Standards for small parcels <br /> 12. Remove erosion conlrol measures upon completion o'the project prior lo final approval of the permit. <br /> ' 13`: All excavaled material from foundation, sidewalk and driveways shall be hauled to an approved, <br /> permilted site. No wasting of material is allowed on this building lot. <br /> �. No dirt, mud, rocks or debris lo be iracked onto roadway. <br /> �i� No building materials lo be slacked on sidewalks and sideH-alks lo be kept clean and open for <br /> pedestrian Iravel. <br /> 1 ti Fldpist water meler I�ox 1"above sidewalk grade. <br /> i� Rernove and replace curb, gutter and sidewalk as per City o( Everett St2ndard Plan #'s 305A&306 on <br /> this proposaf= fronlage as directed by the Public Works Inspeclor (i e. all unused driveways and any <br /> broken or damaged area must be replaced). <br /> 1£3. Install a Type I concrete driveway per Ciry of Everelt Slandard�307. <br /> 19 Pave driveway irom the(ront properry line oul to Ihe street pavinc�. <br /> 20 Contact lhe Wzter Dislrict for connecting provisions for this building's water and <br /> sewer services. <br /> 1� A catch basin as per Cily Standard Plan#402 with a gas lrap per�landard Plan #410 is required (or the <br /> parking area. <br /> 22 If a sewer pump syslem is lo be installed, the pressure line must discharge into a private manhole, then <br /> gravily flow across the public righl-of-way. <br /> 23. A sprinkler system is required for this building in compliance with lhe requirements o(NPDA Standards <br /> 13D. <br /> FOR PU6LIC VVORf<S INSP[CTION, Ci1LL RANDY AT 425-339-7d03 !CLIFF AT 425-339-7404 <br /> F':,�'��,���,,._���„ �� <br /> � <br />