Laserfiche WebLink
Jo6 Address: 11329-2nd Avenue S.E. <br /> Plan Check No. : 92/36224 <br /> Page Two of Two <br /> 7, Plans do not show the spaces in existing structure that <br /> adjoin the addition. If any existing windows in those spaces <br /> are removed it must be shown that the provisions of the <br /> Uniform Building Code are not compromised, such as, minimum <br /> light and ventilation requirements are met, and that escape <br /> and rescue windows are not compromised. <br /> 8. The front elevation shows a gabl.e roof at bay above garage. <br /> The framing plan shows a hip roof, neither shows framing <br /> members. Show size, spacing, species and grade of framing <br /> members. <br /> 9, Show cross-section of stairs indicating construction of <br /> stairs and any changes to the existing structure to <br /> accommodate stairs (including minimum headroom) . <br /> 10. Typical wall section does not show a cantilever condition or <br /> a moisture barrier at exterior wall or spacing of 2x4 or 2x6 <br /> studs. <br /> In order for the processing of your application to contin�e, it will <br /> be necessary to provide the Building Department with two complete new <br /> sets of drawings reflecting the corrections requested. <br /> Upon re-submittal of the drawings, your application will be given <br /> priority and plan review will recommence. <br /> All req�ired submittals shall be of sufficient detail and contain <br /> sufficient information to ensure that the proposed structure will be <br /> constructed in compliance with all adopted codes. <br /> Sincerely, <br /> Jeff Heilman <br /> Fngineering Technician <br /> JH:cglbldlJ.46 <br /> �Iv <br />