My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10011 3RD AVE SE BASE FILE 2016-01-01 MF Import
>
Address Records
>
3RD AVE SE
>
10011
>
BASE FILE
>
10011 3RD AVE SE BASE FILE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2017 9:32:11 PM
Creation date
3/7/2017 9:31:32 PM
Metadata
Fields
Template:
Address Document
Street Name
3RD AVE SE
Street Number
10011
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
280
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MEMORANDUM <br /> p0: GORDON WITCNEN <br /> FROM: JANE ZI6MERMAN <br /> DATE: APRIL 23, 1990 <br /> SUBJECP: SEPA N166-88 <br /> In the �bove SEPA, under item M4 in the section titled <br /> "Information for Developer", it is staTed that the on-site <br /> detention volume is required to include the storage lost by <br /> fill.ing of the isolated wetland. This point is not taken <br /> into account in the detention calculations. <br /> The intent of the statement is to address the function of <br /> the isolated wetland in reducing the peak discharge from the <br /> site during a given storm. A decreased discharge calculated <br /> for lhe pre-development design storm results in increased <br /> storage requirements. <br /> The technical release from the Engineering Division of the <br /> Soil Conservation Service entitlad "Urban Hydrology for <br /> Small Watersheds" provides a table of corre::tion factors <br /> given the ratio of the total site drainage area to the area <br /> of ponding or swampy area. For this site, t:hat correction <br /> factor is 0.69, meaning that the peak disch�irge allowed from <br /> the site should be 69� of that calculated without taking <br /> into considerat•ion the storage effects of the isolated <br /> wetland. <br /> However, the peak discharge calculated for this site during <br /> the 2 year, pre-development design storm was a'_ready less <br /> than the minimum discharge that the City of Ev^rett wi.11 <br /> allow. The calculated flow was 0.015 cfs ac opposed to the <br /> City minimum of 0.13 cfs. (The City minimum is calculated <br /> using a 2" borda orifice, the smallest orifice diameter <br /> considered safe for these applications) . Therefcre, a peak <br /> flow of C.13 cfe was used in the detention calculations. <br /> Given that the peak discharge calculated from the site was <br /> Less than the minimum allowed by the City, the application <br /> of the correction factor does not increase the amount of <br /> detention required. Therefore, the amount of detention <br /> calculated does meet the conditions of the SEPA. <br />
The URL can be used to link to this page
Your browser does not support the video tag.