Laserfiche WebLink
I <br /> 1 �` I� <br /> � <br /> CIIECKLIST FOIt SMLMMIHG PODLS <br /> This checY.lisl is provided tu laiilitate plan review lor sWinunin9 puols. Please <br /> complete appropriate sectiuns for your pool tacility as lis[ed. <br /> 1. GENERAL POOL FACILITIES SECTIOH - , 'I <br /> Name of Facility rV oN L % �� I <br /> Location �� Q } �' ''�u � Si, �1 �� � <br /> Owner C'�:o�1i./F_S�PN u Phone S?�-�- 1�=�� <br /> Contractor Phone � '1 i - �-{ � �,� <br /> Design Engineer or ArchitectS �c � c �Phonel�L� -..l � -;�t . ���.��� �l � <br /> New Construction �_ Modification Addition <br /> Provide Pltns and specifications �f the pool . Plans are to be drawn to scale. Plans <br /> sho�ld include: <br /> i� <br /> (a) One plan view � <br /> (b) At least one sectional view <br /> (c) One detailed view of the equipment room layout <br /> (d) One piping schematic showing piping, pipe si2e, inlets, main drains, <br /> � overflow channel or skirtmers, vacuum fittings, and all other <br /> appurtenances h�oked to the pool piping system. <br /> (e) Overall plan showing pool in relation to other facilities (can be with <br /> '� (a) abovel . <br /> (f) Specifications on appropriate equipment, i .e. filter, pump, chemical <br /> feeders, etc. <br /> II. GENERAL POOL CHARACTER[STICS <br /> Pool Shape: Rectangular: �_ Oval : Kidney: Other: <br /> Poll Dimensions: Length: � � , W�dth; ^� � � Pool Depth Range '� to � <br /> � (ShaTlou) TDeep <br /> Total Surface Area of Pool (Value A) ( '��'1 : Square Feet. , <br /> Surface Area of Fool less than 5'6" depth Va ue S) �I(l7l , <br /> A - S + 5 <br /> Compute maximum bathin load: �� 10 = � (�alue OL) Maximum Dathing Load. <br /> Pool Capacity: !) Gallons — <br /> Material Finish o Poo : Concrete: ��' Metal : Tile: Other (Specify) <br /> Deck Area: Total Area: b0 �quare feet. <br /> ileck Nidth: � lMinimum c' )� ^ � <br /> Specify 7ype of Non-slip�imsh on�eck �;�p e l ;.� � � '•-c. <br /> Specify slope to drain I " (Minimum 4 t. . <br /> Required deck area (pub ic poo s - Take (Value BL) computed above times ',6 = �.)l . sq. ft. <br /> Inlets 8 Outlets: Specify Y of Inlets �- . Specify flow capacity of inlets�,� gpm. <br /> Specify square inches of o enin in main drain �, square.inches. <br /> Specify width of openings etueen grates I �� maximum 1/2"). <br /> Determine maximum velocity through main drain at 100T of maximum pump f1oWG:: �� fps <br /> (maximum 1 1/2 fps) �, � <br /> Indicate how main drain is secured to prevent unauthorized tampering�� /�: rr�., . , <br /> 0.ecirculation: Note turnover rate��,,�r1 gpin requirecl for this pool . <br />