Laserfiche WebLink
.' � �^ <br /> Pavel Gudev <br /> Plan Check N55830 <br /> August 4, 1997 <br /> Page 2 of 2 <br /> 8. Show all windows on elevation view. Mark out or remove windows that are not going to be <br /> installed on elevation views. <br /> 9. Specify roof slope(s) of all azeas on the roof plan and elevation views. <br /> 10. Provide detail of attic ventilat,on type, size, and location. Show the required ne� area <br /> calculation. <br /> I 1. Specify post/beam, post footing connections. A positive connection is required for uplift and <br /> lateral displacement (2324 UBC). <br /> 12. Specify size, thickness and reinforcing of footing(s) at end of 6-3/4 x 21 G.L.B. <br /> 13. Call out minimum 3-1/2" concrete (floor - slab-on-grade) reinforcement and moisture <br /> barrier, if any, on foundation plan. <br /> Pcepaze a response letter showing w�here each item in this correction letter is addressed on the plan <br /> set. <br /> Upon resubmitt�ll of the drawings, your application will be given priority and plan review will <br /> commence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to ensure that <br /> the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> � � <br /> Jeff Heilman <br /> Devclopment Technician <br /> JI i:jcl/&9Rltrs.dx(DV.2-Jl <br />