Laserfiche WebLink
. COMPLIANCE NWEC LOWRISE�RESIDENTIAL COMPLIANCE CHECKLIST <br /> REOUIRED� Electrically heated dwellings, s 3 storlas, Zone 1, Western Weshington <br /> iN5PECT10N �MPORTANT: Please supply Informatlon requested In the appropriate <br /> APPROVED sheded boxes beiow. Dlarepard boxsa thet don't describe your bulldlnp or <br /> equlpment. DQNQIplece checks In the two laft columns. <br /> FINAL PNASE <br /> i <br /> ❑ Crawl space Floors wfll be Insulsled without compression, and with adequate sup rt to: <br /> O R30(Ch#6 Option I) ❑ R19 (Ch q6 Optione II, III, IV) ❑ R�Ch#4,5,or 7) <br /> ❑ Non•vaulted, ettic ceillnpt will be insulated wRhout compression to: <br /> ❑R-38 (Ch#6, all options) 0 R 38 rCh#4,5,or� <br /> p ❑ Interlor Below prad� walls are Insulated without compression to R19 instead oi exterior R10. <br /> p Door syst�mi meet: ❑U.19(ChN6, (oplions I, II, III) ❑U.22(Chli6, (option IV pU:� #4or5) <br /> ❑ Loosaflll Insulation OK if: <br /> 1) maximum ceiling slope not > 2 1/2 in 12 <br /> 2) a30"of clear dislance from top of boriom chord to the undercide of roof sheathlnp at ihe roof ridge. <br /> ❑ 8 mll potyethylene or other approved ground cover lapped 12"at all�oints and to foundation wall <br /> ❑ Clearances meet listed minimums between Insulation and: <br /> 1) chimney 2) Iight Iixtures 3) IC rated recessed lights (0"c!earance OK) <br /> ❑ Attic hatch is insulated to requfred ceilfng R-value and is weatherstripped. <br /> ❑ All exterlor and/or parape to home doors areweatherstripped. <br /> ❑ ❑ Reclrculating aervice hot water pipinp is insulated as checked below(see Uniform Building Code, <br /> Sections 7712 81713,ilame spread and smoke density requirements ) <br /> 1) 1-1/2" Insulation for maln Iines in attic and crawlspace. <br /> 2) 1" Insulation for branch Iines in attic and crawl space. <br /> ❑ Mlnlmum of one thermostat per HVAC system with proper F range oi 55-75' (heating). <br /> � � Readlly acceaslble means to restrict or shut-off heatlnp Input to eac;i zone orfbor not <br /> coMrolled by a thermostat. <br /> ❑ Thermostat setback is in place and readily accessible.. <br /> 0 � Backup heatlnp system controls must prohibit operation when primary heating system is <br /> operating. <br /> p ❑ Machanlcel ventllatlon system must have a means for volume reductfon and shut-off. <br /> � � Supply ducta must have volume dampers to balance system. <br /> ❑ ❑ SuRply and retvrn aly ductwork is required to have sealed duct Joints in unconditioned spaces <br /> and: [�i11 insulation (Ch#5 and 6, all optfons) OR ❑ R_(Ch 7f4 Approach) <br /> ❑ Electrlc water heeter(s) has : <br /> 1) separate power shut-off 3) ASHRAE 90A-80 label on tank <br /> 2) noncompressible R10 pad (unheated apaces only) <br /> ❑ Shower(s) has a means to Iimft flow to 2.75 gpm or less <br /> .. . _ ,. M : . a , , <:. . <br /> Flreplacea will ❑ wlll not be Installed: Mir. Model <br /> Woodatoves O wlll O wlll not be Installed: Mir. Model <br /> p ❑ All tireplacelstove(s) havo: 1)6 sauare inch combustion air supply directly conected to the fire box <br /> 2)Combustion air duct with readily accessible, tight fitting damper. 3) Tight tiriing glass or metal doors <br /> O O Masonry fireplace(s) has a tight litting flue <br /> damper with readily accessible, manual control(s). <br /> NWEC Flnel phase requlrements: <br />�� Approved by: <br /> Dete <br /> I <br /> WEEB�PRIL GO Pep9 7 of 7 <br /> I <br />