Laserfiche WebLink
, � 0 S- o a`�D <br /> ENERGY NOTES - �LECTRIC HEAT <br /> General Provisions: <br /> 1 . Mechanlcal spot exhaust ver,tilation, ducted to the exterior, 1s <br /> required in all bathrooms (50 cfm) :nd kitchens (100 cfm). Ba�kdraft <br /> dampers are required. <br /> 2 Outside a1r is required to be supplied into the conditioned space. <br /> See ventilatien reQuirements. <br /> 3 oriented�strandsboardsdare stamoeda°ExposureaIa�orafExte�lor�� and <br /> 4. liater heater storage tank labeled <br /> as meeting ASHRAE standard 90A - <br /> 1980 or insulated to R-16. <br /> 5 overruninsulatedroreconcretesfloors�aced on an R•-10 pad if located <br /> 6. Insulate hot and cold waterpipes to R-3 in unheated areas. <br /> 7. Shower regulations to limit hot water discharge to 2.75 GPM. <br /> 8. Heating ducts must be insulated to R-11 . <br /> 9. Woodstnves and fireplaces have tight-fitting doors. <br /> 10. fjoebo%V2Mithdaccessiblesdamper u(Mine c�6bsq�.iin.anetdfree vent area) <br /> 11 . Fireplaces have tight-fitting flue dampers. <br /> 12, qll gas or o11 combustion appliances have direct vent or forced draft <br /> venting. <br /> 13. Recessed lights are I.C. rated, double wall can lights. <br /> 14. 6 mil black visqueen ground cover in craWl space. <br /> A1r Sealing: <br /> l . Al1 plumbing, electrical and HVAC penetratlons in floors, wall and <br /> ceilings are caulked and sealed. <br /> 2. Where penetrations need a firestop, discuss with your building <br /> department. <br /> 3. Electrical outlet and liyht swi �,;h hoxes on exterior walls must be <br /> sealed at the back. of the receptical or sealed with face plate gaskets. <br /> 4. Seal rim �oist between heated floor or use a product like "tyvek" on <br /> exterior. <br /> continued next page <br />