PUBLIC WORKS PERMIT COMMENTS <br /> '� 4.�� Connect side sewer per City Standard #601. <br /> ,\ / <br /> 5. Connecl side sewer per City Standard #'s C01, 602, R04. <br /> 6. Connecl all rooftop do�vnspouts to the side sewer. <br /> l 7..� Connect roo(lop downspouls to lhe drainage syslem provided for this lot. <br /> 8. Rooitop runo(f musl be discharged to a roof downspout in(iltration system per City of Everett Storm <br /> Manual 3-2.6.2. The approximate size lrench is 3.5'wide, 2'deep and 25' long. See attacliment for <br /> more details. <br /> 9. The contraclor must meet with lhe Public Works Inspecfor to discuss potential drainage routing prior to <br /> bec�inning the project. <br /> 10. Install erosion control measures as delermined by the Public Works inspector, such as silt fence, straw <br /> bales, swales, or erosion blankets. <br /> 11. Install erosion control measures per City of Everett Standards for small parcels <br /> 12. Remove erosion conlrol mzasures upon complelion o(the project prior to final approval of lhE permit. <br /> 13. All excavaled material from foundation, sidewalk and driveways shall be hauled to an approved, <br /> permilted site. No wasling of material is allowed on lhis building lot. <br /> � 14� Nu drt, mud, rocks or de�ris to be tracked onto roadway. <br /> 15. No building materials to be slacked on sidewalks and side�valks to be kept clean and open tor <br /> pedeslrian travel. <br /> 16. Adjust water meter box 1"above sidewalk grade. <br /> 17. Remove and replace curb, gultei and sidewalk as per City o(Everett Standard Plan #'s 305A& 306 on <br /> this proposaPs frontage as directed by the Public Works Inspector(i.e. all unused driveways and any <br /> broken or damaged area musl be replaced). <br /> 10. Inslall a Type I concrete driveway per Cily of Everett Standard #307. <br /> 19. Pave driveway from lhe front property line oul to lhe slreet paving. <br /> 20. Conlacl lhe Waler District(or connecling provisions for this building's water and <br /> sewer services. <br /> 21. A catch basin as per Cify Standard Plan�402 wilh a gas trap p=r Standard Plan#410 is required (or lhe <br /> parkinc�area. <br /> 22. I(a sewer pump syslem is lo be installed, lhe pressure line musl discharge into a private manhole, then <br /> gravity Oow across the public righl-of-way. <br /> 23. A sprinkler system is required for this buildinc� in compliance with the requirements of NFDA Standards <br /> 13D. <br /> FOR PUBLIC INORKS INSPECTION, CALL f2ANDY AT 425339-74031 CLIFF AT 425339-7404 <br /> I <br /> r <br /> P1;Ccn��mcras <br /> ���� <br />