My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8812 3RD AVE SE 2016-01-01 MF Import
>
Address Records
>
3RD AVE SE
>
8812
>
8812 3RD AVE SE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2017 10:36:52 PM
Creation date
3/7/2017 10:36:33 PM
Metadata
Fields
Template:
Address Document
Street Name
3RD AVE SE
Street Number
8812
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
138
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Plan Check No. 36989 <br /> June 26, 1992 <br /> Page Two of Three <br /> S. Walls and floor separat_ing dwelling units in the same <br /> building shall be of not less than 1-hour fire-resistive <br /> construction. section 12o2 (b) . <br /> 9. A Group R, Division 1 Occupancy moreareafeet aboveltheifirst <br /> height or havinq more than 3,000 squ <br /> story shall eS Sectfor.u1202(b)resistive construction <br /> throughout p <br /> 10.Provide smoke detectors per Section 1210. <br /> 11 Illustrate handrdailt heighta le gthS clearance6(etc. <br /> 12,provide a quardrailei Sect one1711f1 Illustrate the the open <br /> side of the stair p hei ht, etc. <br /> quardrail, ballaster spacing, 9 <br /> 13.Protect usable apace under the stair per Section 3306(m) . <br /> 14.Clothes dryers must be vented to the exterior of the <br /> buildinq. <br /> 15.Indicata bath, kitchen, laundry room and whole house <br /> Ventilation andBlndoor1Air QualitytCode3 (v.iaA.Qn;ton State <br /> 16.Indicate outdoor air inlets per Section 3Q2.6.2. V.I.A.Q. <br /> Code. <br /> 17.provide qround fault interupter circuits for kitchen, bath <br /> and laundry areas. <br /> 18.Provide outlets in hall, entry and laundry areas (minimum one <br /> outlet in each) . <br /> 19.Please clarify the elevation change (step?) between the <br /> second floor level and the exterior deck (the deck is framed <br /> with 2x12�s, 2x sle.epers and 2x decking. The second floor is <br /> framed with 2x10's) . <br />
The URL can be used to link to this page
Your browser does not support the video tag.