Laserfiche WebLink
� - , <br /> WATTSUN 5.2 1991 WA STATE ENERC,Y CODE COMPLIANCE REPORT 05/22/92 <br /> FILE: A;\0592083.WS HOUSE ID: 4 plex 2 STORY <br /> ---___—°______=====g=______�_______________________ <br /> Struc Mass Li ht Frame Sheetrock walls M- 3.000 3448 10344 <br /> -------------------------------------------------------------------------------- <br /> HEATING/COOLING/VENTILATING SYSTEMS <br /> PROPOSED <br /> Heating System Type: Electric: Zoned <br /> SXstem Efficiency: 100 $ <br /> Modlfied Efficiency: 100 $ <br /> Design ACH: 0.60 <br /> Heating Load(at 50F dt) : 38257 Btu/hr <br /> System Size: 11.2 kW <br /> Maximum Size @150$: 16.8 kW <br /> Averaqe Annual Heat: 16399 kWh <br /> Annual Cost: $ 902 <br /> Ventilation System: Integrated Spot <br /> & Whole House <br /> Coolinq Load(at OF dt) : 26350 Btu/hr <br /> Recommended Size @125$: 3.0 tons <br /> Solar Access: Partially Shaded <br /> -------------------------------------------------------------------------------- <br /> GLAZING ORIENTATION <br /> PROPOSED PROPOSED <br /> South: 89.2 ft2 North: 89.2 ft2 <br /> Southeast: Northwest: <br /> East: 89.2 West: 89.2 <br /> Northeast: Southwest: <br /> -------------------------------------------------------------------------------- <br /> Economic and energy consumption estimates are designed for comparative <br /> purposes only. Actual cost for heating will vary depending on weather <br /> conditions, occupant lifestyle and other facLors. <br /> _____________________________________ Page 2 =__________________________________ <br />