Laserfiche WebLink
Plan Check No. 36862 <br /> • July 21, 1992 <br /> Page Two of Three <br /> ✓8. A weather-resistive barrier must be applied to exterior walls as specifieci in Section <br /> 1707(a). <br /> ✓9. Safety glazing is required in hazardous location. Section 5406(d). <br /> ✓10. Walls and floor separating dwelling units in the same building shall be of not less than <br /> ` ,�,� 1-hour fire-resistive construction. Section 1202(b). <br /> µ��,�,,, <br /> � ✓11. Provide smoke detectors per Section 1210. <br /> ��pNy�- 12. Provide a handrail at the stair per Section 3306(j). IDustratc handrail, height, length, ' <br /> clearance, etc. <br /> �'�� (,J� <br /> 3� �3. Protect usable space under the stair per Section 3306(m). <br /> V14. Clothes dryers must be vented to the exterior of the building. <br /> ✓ 15. Indicate bath, ldtchen, ]aundry room and whole house ventilation fans and sizes per <br /> Section 302 Washington State Ventilation and Indoor Air Quality Code (V.I.A.Q.). <br /> ✓ 16. Indicate outdoor air inlets per Section 302.6.2. V.I.A.Q. Code. <br /> �7. Provide ground fault interrupter circuits for kitchen, bath and laundry azeas. <br /> vf8. Provide oudets in hall, entry and laundry azeas (minimum one outlet in each). <br /> �/�LEt%�--19. Indicate deck edge (corner) supports and footings. <br /> �20. Provide a mechanical connection of per post to footings and beams (i.e, metal <br /> framing connector or similaz to provide lateral restraint). <br /> �I. Provide a 1/2 inch minimum space between end beam/post at the concrete foundation. <br /> �2 aclequate air flow and weep holes and flashing should also be prov ded t p�d �low <br /> bottom. <br /> ✓23. Sills shall be as required by Section 2516(c)3: <br /> �34. Provide a double 2x6 top plate at the second floor of the exterior wall and at the roof <br /> of the exterior wall. <br />